_482615_RE1304003 8mm ZS feeder maint.pdf - 第12页
Trained Customers Service Information 12 / 27 SI 1304003E- 00 0 = 8mm ZS feeder maintenance procedures 1 2. 8 Replac e the unclamp lev er 2.8 .1 Remov e t he unclamp lev er Step 1 Remove the tail cov er ass y referring t…

Trained Customers
Service Information
11/27
SI1304003E-000 = 8mm ZS feeder maintenance procedures 1
2.7.2 Install the operation switch
Step 1 Put a new operation switch harness through the cut out part of the top tape box. Then
remove the release liner on the back of the operation switch and attach the switch to
the specified position on the top tape box.
Attach the harness of the operation switch to the double-sided adhesive tapes on the groove
under the membrane cover and lead the harness into the EL box.
Note
If adhesion of the adhesive tapes is weak, replace it with a new one available on the market.
Step 2 Make sure that the stopper of the connector of the feeder board is unlocked. Then
insert the connecting part of the harness into the connector and lock the stopper.
Note
Jiggle the harness gently to check if the harness is securely connected.
Step 3 Firstly, insert the claws at the lower part of the membrane cover into the EL box. Then
insert the claws in order from lower to upper ones to attach the cover to the body.
Note
The claws of the membrane cover are small and fragile. Take care not to break the claws in
this step.
Step 4 Install the top tape box cover to the feeder body referring to “2.2 Replace the top
tape box cover”, step 2.
Step 5 Install the EL box cover to the feeder body referring to “2.3 Replace the EL box
cover”, step 2.
Step 6 After replacing the operation switch, set the tape feeder to a feeder station and press
the operation switch to check if it works properly.
Release liner
Double-sided
adhesive tape

Trained Customers
Service Information
12/27
SI1304003E-000 = 8mm ZS feeder maintenance procedures 1
2.8 Replace the unclamp lever
2.8.1 Remove the unclamp lever
Step 1 Remove the tail cover assy referring to “2.2 Replace the top tape box cover”, step 1.
Step 2 Remove the E-ring on the shaft where the unclamp lever is installed using a flat-blade
precision screwdriver.
Note
Take care not to lose the E-ring in its removal work. The E-ring is easy to drop and become
misplaced.
Step 3 Remove the shaft and the unclamp lever from the top tape box.
Note
The unclamp lever incorporates small parts related to the unclamp wire. Take care not to
lose the small parts in this step.
E-ring
Unclamp lever
Shaft
Unclamp lever
Shaft
Unclamp wire related parts

Trained Customers
Service Information
13/27
SI1304003E-000 = 8mm ZS feeder maintenance procedures 1
2.8.2 Install the unclamp lever
For information about the unclamp wire related parts, see “ZS FEEDER User's Manual”,
chapter 2 replacing parts.
Step 1 Install the unclamp wire related parts on the unclamp lever.
Step 2 Set the unclamp lever and its shaft on the top tape box
Step 3 Set the E-ring in the shaft’s groove with the E-ring’s flat side facing upward. Then
install the E-ring using the needle-nose pliers.
Step 4 Install the top tape box cover referring to “2.2 Replace the top tape box cover”,
step 2.
Unclamp wire
Unclamp lever
Tension spacer 1
Tension spacer 2
Tension spring
Top tape box
Shaft
Unclamp lever
E-ring’s flat side