00194547-03.pdf - 第13页
Installation Manual Station Software Version 601.02 SP1 Edition 10/2005 13 of 82 3.2.3 Station computer Name SMP16-CPU086 CPU / clock frequency P M / 1.6 GHz RAM 768 MB Hard disk 40 GB CD-ROM drive Yes Serial interfaces …

Installation Manual Station Software Version 601.02 SP1 Edition 10/2005
12 of 82
3.2.2 Network configuration
SIPLACE X series
Station computer
Machine controller
10Base-T
100Base-T
Private network between
station computer and
machine controller
SIPLACE LAN
SIPLACE Pro
Twisted Pair TP
(100 MB)
Twisted Pair TP
(10 MB)
Fig. 3-2: Network connections between the machine and SIPLACE Pro using the example of the SIPLACE X series
A separate private network (100 Mbit) is set up between the station computer and the machine
controller via a subnet mask.
Fixed IP addresses for the station computer and the machine controller can thus be assigned for all
SIPLACE machines. These IP addresses are not known outside the private network, for instance in
the SIPLACE LAN.
These IP addresses need not be further configured by the operator while the station software is
being installed.
IP address, station computer 192.168.255.249
IP address, machine controller 192.168.255.250
Subnet mask, station computer/machine controller 255.255.255.248
IP address range, SIPLACE LAN 172.22.xxx.xxx
Subnet mask, SIPLACE LAN 255.255.0.0
Table 3-1: Network configuration

Installation Manual Station Software Version 601.02 SP1 Edition 10/2005
13 of 82
3.2.3 Station computer
Name SMP16-CPU086
CPU / clock frequency P M / 1.6 GHz
RAM 768 MB
Hard disk 40 GB
CD-ROM drive Yes
Serial interfaces 2
Network 1 x 10/100Base-T
2 x 10Base-T
6-port hub
Table 3-2: Station computer hardware
3.2.4 Machine controller
Name SMP16-CPU076
CPU / clock frequency Celeron / 650 MHz
RAM 128 MB
Hard disk 40 GB
Floppy drive 3.5", 1.44 MB
Network 1 x 10/100Base-T
Table 3-3: Machine controller hardware
Installation Manual Station Software Version 601.02 SP1 Edition 10/2005
14 of 82
4 Installation instructions
4.1 Automatic BIOS settings at the station computer and the
machine controller
Before the BIOS settings on the station computer and the machine controller can be performed
automatically, you must first create a setup CD for the BIOS settings on the station computer and a
setup floppy for the BIOS settings on the machine controller. To do this, you need a Windows XP
computer which has a CD drive, a CD-RW drive and a floppy drive.
The image files required for creating the setup CD/floppy are in the "BIOS-Images" folder of the CD
for version 601.02 of the software.
4.1.1 Creating a setup CD and making the BIOS settings on the station computer
→ Insert an empty writable CD in the CD-RW drive on any computer equipped with a CD writer.
→ Insert the CD for version 601.02 of the software in the CD ROM drive.
→ In the Windows Explorer, open the "BOIS-Images" folder on the CD.
→ Open the image file "CPU086_BIOS_Einstellungen.iso" using the installed CD writing program
and follow the instructions on screen.
→ Once the CD has been written, remove the CDs from the drives.
→ Insert the CD you have created in the CD ROM drive of the station computer and boot from
the CD by switching the machine on. The BIOS settings are now performed automatically.
→ After the settings have been made, remove the CD from the drive and switch the machine off
again.
4.1.2 Creating a setup floppy and making the BIOS settings on the machine
controller
→ Insert the CD for version 601 of the software in the CD ROM drive.
→ Insert a formatted floppy (3.5", 1.44MB) into the floppy drive.
→ In the Windows Explorer, open the "BOIS-Images" folder on the CD.
→ Double-click the self-extracting EXE file "CPU076_BIOS_Einstellungen.exe" and follow the
instructions on screen.
→ Once the floppy has been written, remove the floppy and the CD from the drives.