00197193-01_IM_SIPLACE_EDM_2_0_EN.pdf - 第53页

EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition SkipOptimisationResultsForNotifications Boolean (false) M;C;D If set to true the optimization results (head steps…) will not be transferred to the master server when…

100%1 / 74
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
ForceCategoryEntryInCommentDialog Boolean
(true)
L; D
This value indicates whether the
comment category name may be
empty.
ClearCommentInCommentDialog Boolean
(true)
L; D
This value indicates whether the
previously entered comment is active
when opening a comment dialog.
ClearUserInCommentDialog Boolean
(true)
L; D
This value indicates whether the
previously entered user name is active
when opening a comment dialog.
ClearCategoryInCommentDialog Boolean
(true)
L; D
This value indicates whether the
previously selected comment
category is active when opening a
comment dialog.
SetUserInCommentDialogTo String
(“”)
L; D
The User value can be set to a fixed
value. There are two special values:
“[SiplaceProUserName]” and
“[WindowsUserName]” that will be
replaced if the SIPLACE or Windows
user name.
disableUserEntryInCommentDialog Boolean
(false)
L; D
Disable the input for the user name (if
user name entry is disabled the
ForceUserEntry… setting is ignored).
DisableEdmToolQuitMenu Boolean
(false)
T; D
Option to disable the “Quit”-Menu in the
EDM Tool.
LimitEdmToolExitToAdmins Boolean
(true)
T; D
Option to disable the “Quit”-Menu in the
EDM Tool for normal users.
AllowQuittingEdmToolWithActiveBlockingReasons Boolean
(false)
T; D
Option to enable Quitting the EDM Tool
while a Comment or Push Confirmation
Dialog is displayed.
EdmConfigurationService.Binding.OpenTimeout Time
(PT1M)
All; D
The Open-Timeout of the EDM
Configuration Server Web-Service /
Client.
EdmConfigurationService.Binding.CloseTimeout Time
(PT1M)
All; D
The Close-Timeout of the EDM
Configuration Server Web-Service /
Client.
EdmConfigurationService.Binding.ReceiveTimeout Time
(PT10M)
All; D
The Receive-Timeout of the EDM
Configuration Server Web-Service /
Client.
EdmConfigurationClient.KeepAliveIntervall Time
(PT1M)
All; D
Interval a configuration client sends a
“KeepAlive” request to the configuration
server. Must be smaller as the receive
timeout.
EdmConfigurationService.Binding.MaxConnections Integer
(50)
All; D
Maximum number of connections to the
EDM Configuration server.
PreservePcbBarcodesDuringMasterImport Boolean
(true)
M;C;D
If set to “true”, do not overwrite the PCB
barcodes in the master database with
the (local) barcodes from the Line
Server.
52
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
SkipOptimisationResultsForNotifications Boolean
(false)
M;C;D
If set to true the optimization results
(head steps…) will not be transferred to
the master server when changing a job
at the line.
UseSmtpAuthentification Boolean
(false)
F; M; D
Enable (experimental) authentication
with username and password when
sending E-Mail notifications.
CompressionHelper.ZipCompressionLevel Integer
[0..9]
(9)
All; D
Compression rate for the EDM data
transfer. Specifies the compression
level of the algorithm used; A lower
compression rate can be required if
memory problems arise as a result of
large volumes of data during
compression.
Value range: 0 through 9.
CompatibilityMode Boolean
(false)
L; M; D
If true: Allows restricted operation of an
EDM Line Server together with an EDM
1.0 Master Server. (See section 4.3)
Caution: This mode must not be used
for long-term mixed operation, but only
for step-by-step upgrading the EDM
system from 1.0 to 1.1. The Modified
Object protection is inactive when the
compatibility mode is active!
Note: This setting is not required when
upgrading from EDM 1.1 or higher.
Table 6-10: Settings in the SystemConig.xml file
6.3.6.1 Server type
Key: serverType
Type: Enum
Values: NONE
LINE
MASTER
BOTH
CLEARINGPOOL
CONFIGSERVER
CONFIGMASTER
CONFIGLINE
ALL
Line + Master
Config Server + Master
Config Server + Line
Config Server + Master + Line + CP + …
Valid for: All EDM Computers running an EDM Service
Description: Specifies the type of installation. The EDM server is started as a Line Server,
Master Server or hybrid depending on this setting.
NOTE: The hybrid settings “BOTH” and “ALL” should only be used for test
purposes!
NOTE: This value is replaced with the value from the MachineConfig.xml (see 0).
This is the fallback value for EDM Computers that have no entry in the Machine
Configuration. The default value is “NONE”.
53
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
6.3.6.2 Help folder
Key: helpDirectory
Type: Path
Default: [AppDir]\help
Valid for: Line server
Master server
Clearing pool
EDM Tool
Description: Folder for online documentation
6.3.6.3 Distribution list for EDM notifications
Key: notificationDistributorClass
Type: Class
Default: Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Valid for: Master server
Description: Class, i.e. implementation of the notification service. At present, distribution via
email is available using the default value as a reference.
6.3.6.4 Configuration of EDM notification traffic
Key: notificationDistributorConfiguratorClass
Type: Class
Default: Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Valid for: Master server
Description: Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email
service referenced using the default value is currently supported.
6.3.6.5 Notification interval
Key: notificationInterval
Type: Time
Default: P0Y0M0DT0H15M0S (= 15 minutes)
Valid for: Line server
Description: Time period during which the change notifications will be collected on the Line
Servers before they are sent to the Master Server. The other options are as follows
(from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
The period should not be shorter than 5 minutes.
54