EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
6.3.6.6 Notification storage
Key: notificationStorage
Type: Endpoint
Default: notificationStorage
Valid for: Line server
Description: Buffer for collected change notifications.
6.3.6.7 Master server
Key: masterServer
Type: String
Valid for: Line server
Master server
Clearing pool
Description: Network ID of the Master Server. Windows computer name only. IP addresses are
not permitted.
6.3.6.8 Transceiver
Key: transceiverClass
Type: Class
Default: Siemens.SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for: All EDM Applications
Description: Implements the data transfer between the Line Servers and Master Server. This
entry must be identical on all installed systems. The exact format of the "endpoint"
values depend on this value. The default setting uses MSMQ to transfer the data.
Endpoint: An endpoint entry has the following format for the MSMQ transceiver:
Private$\[queue-name].
Note that private queues absolutely must be used here. Only private queues can
be used in both a domain/active directory-based network environment as well as in
a pure workgroup installation.
6.3.6.9 Outgoing requests
Key: masterRequests
Type: Endpoint
Valid for: Line server
Clearing pool
Description: Target address for service requests sent by a Line Server to the Master Server.
The setting must be identical to the Incoming Requests setting on the Master
Server.
55
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
6.3.6.10 Outgoing change notifications
Key: masterNotifications
Type: Endpoint
Valid for: Line server
Description: Target address for change notifications sent by a Line Server to the Master Server.
The setting must be identical to the incoming change notifications setting on the
Master Server.
6.3.6.11 Incoming requests
Key: incomingRequests
Type: Endpoint
Valid for: Master server
Description: Endpoint at which the Master Server listens in for incoming service requests.
Determines the value for outgoing requests on the Line Servers.
The value must be different from the value for incoming change notifications.
6.3.6.12 Incoming change notifications
Key: incomingNotifications
Type: Endpoint
Valid for: Master server
Description: Endpoint at which the Master Server listens in for incoming change notifications.
Determines the value for outgoing change notifications on the Line Servers.
The value must be different from the value for incoming requests.
6.3.6.13 Incoming Clearing Pool requests
Key: incomingClearingPoolRequests
Type: Endpoint
Valid for: Master server
Clearing pool
Description: Endpoint at which the Clearing Pool listens for incoming commands from the
master service.
56
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
6.3.6.14 EDM tool endpoint
Key: edmToolEndPoint
Type: Endpoint
Default: EDM_SPI_REMOTE_HOST:9002/EdmTool
Valid for: Master server
Line server
EDM Tool
Description: Endpoint for entering change notifications. The default value means that the
comment dialog boxes always open on the computer at which the SPI event was
triggered that caused the notification which requires a comment (if an EDM tool is
installed there).
Replace EDM_SPI_REMOTE_HOST in the configuration file of the Line Server with
the host name of this computer, if the line engineer shall enter the comments at a
different computer.
6.3.6.15 Endpoint configuration
Key: endpointConfig
Type: Section
Valid for: Master server
Description: This section contains pairs of values in the form of:
<add key="[hostname]" value="[Endpoint]"/>
There is one pair of such values for each Line Server. This list describes the
connections from the Master Server to the Line Servers to be used.
The network ID (not the alias) of the computer concerned must be entered under
hostname. You can also enter "*" or "all" as the value for hostname. This is
then used as the default value when no entry can be found for a specific Line
Server.
Important: All Line Servers should always be listed in every configuration file. In
particular, the name of the local computer must be included (or at least an entry for
"*").
6.3.6.16 Communication timeout
Key: communicationTimeout
Type: Time
Default: P0Y0M0DT0H1M0S (= 1 minute)
Valid for: Line server
Master server
Clearing pool
57