00197193-01_IM_SIPLACE_EDM_2_0_EN.pdf - 第58页
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition Description: Time period in which a message must be received from a particular communication partner. The setting should generally n ot be changed. The other options…
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
6.3.6.14 EDM tool endpoint
Key: edmToolEndPoint
Type: Endpoint
Default: EDM_SPI_REMOTE_HOST:9002/EdmTool
Valid for: Master server
Line server
EDM Tool
Description: Endpoint for entering change notifications. The default value means that the
comment dialog boxes always open on the computer at which the SPI event was
triggered that caused the notification which requires a comment (if an EDM tool is
installed there).
Replace EDM_SPI_REMOTE_HOST in the configuration file of the Line Server with
the host name of this computer, if the line engineer shall enter the comments at a
different computer.
6.3.6.15 Endpoint configuration
Key: endpointConfig
Type: Section
Valid for: Master server
Description: This section contains pairs of values in the form of:
<add key="[hostname]" value="[Endpoint]"/>
There is one pair of such values for each Line Server. This list describes the
connections from the Master Server to the Line Servers to be used.
The network ID (not the alias) of the computer concerned must be entered under
hostname. You can also enter "*" or "all" as the value for hostname. This is
then used as the default value when no entry can be found for a specific Line
Server.
Important: All Line Servers should always be listed in every configuration file. In
particular, the name of the local computer must be included (or at least an entry for
"*").
6.3.6.16 Communication timeout
Key: communicationTimeout
Type: Time
Default: P0Y0M0DT0H1M0S (= 1 minute)
Valid for: Line server
Master server
Clearing pool
57
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
Description: Time period in which a message must be received from a particular communication
partner. The setting should generally not be changed. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
6.3.6.17 Use advanced EDM notification filtering
Key: useAdvancedNotificationFiltering
Type: Boolean
Default: true
Valid for: Master server
Description: Activation/deactivation of direct import/rejection of notifications by the Master
Server.
If these filters are deactivated, all notifications are entered in the Clearing Pool. If
they are activated, changes to objects can be accepted/rejected without first being
displayed in the Clearing Pool (for configuration, see 5.3.6.2 and 5.3.6.3)
6.3.6.18 Modified object protection
Key: useModifiedObjectProtection
Type: Boolean
Default: true
Valid for: Line server
Description: Activation/deactivation of the overwriting of modified objects in the Line Server.
If this object is activated, objects which are currently in the Clearing Pool are not
overwritten with the (older) data from the Master Server during a pull operation.
6.3.6.19 Response timeout
Key: responseTimeout
Type: Time
Default: P0Y0M0DT0H5M0S (= 5 minutes)
Valid for: Line server
58
EDM V2.0 / Installation Manual Ausgabe 04/2012 Edition
Description: Time period in which the Line Server considers a reply to a service request from
the Master Server to be valid. Timing problems can arise here due to the
interaction between SIPLACE Pro and XML Import/Export that may require a
change to be made. However, the timeout should not be set to a value too high
since this can cause the users to become very irritated.
The other options are as follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
6.3.6.20 Compression type and level
Key: compressionType
Type: Enum
Values: None
Zip
Bzip
Default: Zip
Valid for: Line server
Master server
Clearing pool
Description: Compression mode for the data transfer. The setting must be identical throughout
the entire system.
The default setting represents a good compromise between the compression ratio
and processing time. If extremely large amounts of data are transferred by the
customer, it may be necessary to set the compression to Bzip. This method offers
a much higher compression ratio than Zip, but at the cost of longer processing
times. Compression should only be switched off when the amount of data is always
very small (< 4MB).
Even though EDM tries to auto-detect the compression type it is strongly
recommended to use the same compression type in all configurations when
working with different SystemConfigurations for multiple config sets.
6.3.6.21 Client workflow configuration
Key: clientWorkflowConfig (Obsolete now part of the Configuration Set)
Type: File
Default: Clientworkflowconfig.xml
Valid for: -
Description: Definition of the workflow on the EDM Client. The file name is specified relative to
the configuration folder.
59