00197628-02_VD_SIPLACE_Pro_12.1_DE_EN.pdf - 第20页
SIPLACE Pro V12.1 / Softw are Version Descriptio n Ausgabe 05/2015 Edition 20 X4i S placement machi ne – The traveling range in X direction is li mited for the gantries 2 a nd 4 on the X4 i S placement machine . – If a p…
SIPLACE Pro V12.1 / Software Version Description Ausgabe 05/2015 Edition
19
5 Restrictions
In the following, existing restrictions in SIPLACE Pro are described.
Miscellaneous
– 10-fold and 15-fold stick magazines can not be combined on the same linear feeder.
– SIPLACE Pro object names (e.g., recipe) must not exceed 125 ASCII characters (including
folder names). If the station software is 504 or older, these names are shortened to 20 ASCII
characters.
– If various users optimize the same job at the same time, the job which was most recently
completed successfully will overwrite all corresponding recipes
– The operator must manually place manual tray carriers (Carrier 30, Carrier 51, Carrier X,
Carrier SX, Arbitrary Carrier E, Manual Tray Holder E Speed, Manual Tray Holder E Flex) in the
initial setup.
– If you work with reduced acceleration for a component shape, this is seen as a "special case"
and the accuracy of 5% for the simulated Optimizer production time will not be achieved.
– The Optimizer does not check if the tray size is bigger than the carrier.
– The WPC can take up to 10 different component types per level. This restriction does not apply
for machines from station software version 70x.
Station-wise Download
– When the line control server is rebooted, station-wise downloading will be canceled. After
rebooting, you will need to perform a complete line download to restart production.
– Station-wise downloading supports setup changes in asynchronous dual operation only when
you have the same definition for both lanes.
– Station-wise downloading supports synchronous dual operation as of station software version
704.
Changed Values of a Component Packaging
If you change the values for a type of component packaging after this has been assigned to a
component, these values will not be updated for the component concerned.
The component package has to be re-assigned to the component after the component package
values have been modified.
ASCII Centroid Import
If component shapes are selected in the ASCII Centroid Import Wizard, all the existing links
between components and component shapes will be overwritten with the imported information.
WPC5 / WPC6
– Components up to a height of 30mm can be placed with a force of 70N with the WPC5 as of
serial number 1485 and the WPC6 as of serial number C1486 only.
– Components up to a height of 40mm can be placed with the WPC5 as of serial number B3000
and the WPC6 as of serial number C3000.
– Due to the refill module, components > 25mm cannot be positioned on the levels 1 – 3 and
27 – 28 on the WPC6. The levels 4 – 28 will be set up automatically by the SIPLACE Pro
Optimizer. The levels 1 – 3 have to be blocked manually by the operator.
SIPLACE Pro V12.1 / Software Version Description Ausgabe 05/2015 Edition
20
X4i S placement machine
– The traveling range in X direction is limited for the gantries 2 and 4 on the X4i S placement
machine.
– If a pin picker is installed on the X4i S placement machine, the maximum board length is
410mm.
X3 S and X4 S placement machines
If a pin picker is installed on the X3 S and X4 S placement machines, the maximum board length is
410mm.
TrayStak Feeder AX
– The feeder is only supported on the X4i S placement machine and can be positioned on the
locations 2 and 3 only.
– A table of type "DX Table 40 X" has to be configured. Additionally, the "WPC X" table insert has
to be selected s in order to release the traveling range of the placement head for the feeder.
– Only one Dip module LDU-X can be installed beside the feeder.
– If 2 TrayStak Feeder AX are installed together with an LDU-X, the table has to be manually
selected in the Auto Configuration of the station software.
– No nozzle changer support.
– Stationary camera cannot be used.
– CPP placement head supported only.
– Feeder and placement heads are neither controlled in SIPLACE Pro nor in the station software.
– Due to the hardware, the sequence oft he components (chain) cannot be warranted. Therefore,
setup verification with SIPLACE Setup Center cannot be performed.
– After the machine has been rebooted or the feeder has been locked / unlocked, the feeder has
to be manually activated with the buttons on the feeder each time.
– If the feeder is used without a reject conveyor, this may result in incomplete head cycles what
causes a reduced placement performance.
– If there is no space to put back the component, it will be rejected.
C&P20 M 1xxx placement head
– Supported on the CA-series and the SIPLACE X4 S micron / X4i S micron placement machines
only.
Twin VHF 5xx placement head
– Supported on the SX1/SX2 V2 placement machine only.
– No fast gantry exchange possible.
– Must not be used together with the VHF P&P placement head on a machine.
SIPLACE JTF-S
Supported on the SX1/SX2 V2 and the SIPLACE X-series S placement machines only.
SIPLACE Pro V12.1 / Software Version Description Ausgabe 05/2015 Edition
21
SIPLACE JTF-M
– Supported on the SX1/SX2 V2, X4i S micron and the SIPLACE X-series S placement machines
only.
– On the SX1/SX2 V2 placement machine no tape feeder can be placed on the location beside
the JTF-M because no empty tape channel is available.
SIPLACE Wafer Systems
– Supported on the CA-series placement machines only.
– A specific table is required.
Binning can be disabled in SIPLACE Vision
– If binning is disabled in SIPLACE Vision, the measuring in the simulation result of the
optimization will probably take a little longer.
External virtual ink spot handling
– Only possible for stations from station software version 707.0 on.
– Physical and virtual ink spot must not be mixed.
– The board must not contain any active ink spots.
CPP / Twin Head placement heads on SIPLACE CA series
– Stationary cameras may be installed on location 1 and 3 only.
– Twin Head may be installed on location 3 only.
– The CPP placement head is only supported in the high position on SIPLACE Wafer Systems.
Restrictions in the Production Schedule
PCB barcode mode is not supported.
Spring placement process
The board top edge position has to be constant from board to board to allow absolute placement.
Variable board warpages cannot be compensated.
Measuring and changing the component height measured by the component sensor at the
station
– Only for placement heads that are equipped with a component sensor.
– Only for nozzle and component combinations in which the component height is supposed to be
measured with the component sensor.
– The component sensor will not perform any measurement if the component height
measurement is omitted due to SIPLACE Pro rules.