00198761-01_SM_Head_Care_Station_II_EN.pdf - 第10页

1 Introduction 1.3 Staff qualifications and training 10 Service Manual SIPLACE Head Care Station II 11/2019 1.3 Staff qualifications and training Qualified or adequately trained personnel means that these people are fami…

100%1 / 68
1 Introduction
1.2 Other instructions
Service Manual SIPLACE Head Care Station II 11/2019 9
1.2.4.4 Measurements and modifications to ESD modules
Only perform measurements on modules if one of the following conditions is fulfilled:
You are using an earthed measuring device (e.g. via PE conductors)
You are using a potential-free measuring device and discharge the measuring head before
the measurement (e.g.by touching an unpainted metal part of the controller casing).
Always use an earthed soldering iron if you carry out any soldering work.
1.2.4.5 Dispatching ESD modules
Always store modules and components in conductive packaging (e.g. metallized plastic bags
or metal sleeves) and dispatch them in conductive packaging
If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for
example. NEVER use plastic bags or film.
If the module has integral batteries, ensure that the conductive packaging does not touch or
short circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
1.2.5 Release history
Document
SIPLACE Head Care Station II (HCS II)
Service manual
Edition Amendments
11/2019 Initial release
1.2.6 SIPLACE on the World Wide Web (WWW)
Log in to our SIPLACE® homepage at http://www.asm-smt.com.
You can choose between the German and English version.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can also access the MySIPLACE user group. Here you can call
up special information about our placement systems, e.g.
technical documentation
technical information
spare parts lists etc.
Registration for the MySIPLACE user group is very simple:
At the head of the web site, click on
and then on the Register
link.
Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with user name and password.
1 Introduction
1.3 Staff qualifications and training
10 Service Manual SIPLACE Head Care Station II 11/2019
1.3 Staff qualifications and training
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and maintenance of the machine and the add-on devices and are suitably qualified, e.g.:
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
Have been trained or instructed in the upkeep and use of appropriate safety equipment in
accordance with normal safety standards.
Have received first aid training.
1.4 Abbreviations
Abbreviations Description
C&P Collect&Place
C&P12, CP12 Collect&Place head with 12 segments
C&P20, CP20 Collect&Place head with 20 segments
C&P6, CP6 Collect&Place head with 6 segments
CPP Collect&Pick&Place head
CPx Collective term for CPP, CP20, CP12 and/or CP6
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
FHE Fast Head Exchange
HCSII Head Care Station II
PCB Board
P&P Pick&Place
TH TwinHead
VS Vision system type
ID Intermediate distributor
ID1, ID2 Intermediate distributor 1, intermediate distributor 2
2 Spare parts overview
2.1 HCSII Head Unit
Service Manual SIPLACE Head Care Station II 11/2019 11
2 Spare parts overview
2.1 HCSII Head Unit
Spare Parts – Rear View – Part 1
Fig.2: Spare Parts – Rear View – Part 1
Pos. Item Number Description
1 03149124-xx Head care interface HCS II v2.3
2 03158916‑xx PCB-base adapter-Twin-HCS2.3
3 03158917‑xx PCB-base adapter-C&P-HCS2.3
2, 3 03090990-xx MHCU complete compatible
(on Base Adapter Twin / C&P)
4 03055072-xx Modul Head Interface C700B
5 03087842-xx Board Adapter-LP C700B-HCSII
6 03152714-xx Safety switch door HCS2.3
7 03087843-xx Board Adapter-LP CPP/CP20-HCSII
8 03087844-xx Board Adapter-LP Twin-HCSII
9 03085251-xx LabJack UE9