Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Remove the contactors K3 and K4. See 3.5 "Remove the contactors K3 and K4" [}22].
Removal
Open any cable ties where necessary. You may want to mark the positions of the relevant
connections to make clear assignment easier later on.
Fig.22: Removal
Unplug the flat ribbon cable from the
Base Adapter-Twin(3).
Unplug the round cable X91(4) from
the board adapter head interface(6)
(main PCB at the back side).
Unplug the cables X30/X31(5) from the
board adapter head interface(6).
Remove the three screws(2) fastening
the Base Adapter-Twin(1) on the
assembly bracket. Make sure that the
screws are not lost.
Carefully remove the Base Adapter-
Twin(1).
4 Service work – HCSII Head Unit
4.4 Replacing the Base Adapter Twin / MHCU
Service Manual SIPLACE Head Care Station II 11/2019 27
Fig.23: Base Adapter-Twin (upper side)
Fig.24: Base Adapter-Twin (under side)
1 Cable X91 2 MHCU
3 Board Adapter LP Twin-HCSII
[03087844‑xx]
4 PCB Base Adapter Twin HCS2.3
[03158916‑xx]
5 Two cables X30/X31 [03151796‑xx] 6 Screws fastening the MHCU
Remove the cables X30/X31(5).
Remove the Board Adapter LP Twin-HCSII(3).
4.5 "Replacing the Board Adapter LP Twin" [}28].
Replacing/Converting the MHCUs
Remove the screws(6) on the back of the board fastening the MHCU(2) and carefully pull the
MHCU off the base adapter.
CAUTION
Washers/Pins
Make sure that you do not lose the washers.
Make sure that you do not damage the pins under the MHCU.
Installation
Follow the removal instructions in reverse order for installation.
Replace any cable ties which you have removed.
4 Service work – HCSII Head Unit
4.5 Replacing the Board Adapter LP Twin
28 Service Manual SIPLACE Head Care Station II 11/2019
4.5 Replacing the Board Adapter LP Twin
Parts
Fig.25: Board Adapter-LP Twin-HCSII
Board Adapter-LP Twin-HCSII
[03087844‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Removal
Fig.26: Removal
Unplug the flat ribbon cables.
Remove the four screws(1) fastening
the Board Adapter LP Twin on the
Base Adapter-Twin.
Hold the screw nuts(2) from behind
(e.g. with tweezers).
Make sure that the screws and screw
nuts are not lost.
Installation
Follow the removal instructions in reverse order for installation.
Replace any cable ties which you have removed.