00198761-01_SM_Head_Care_Station_II_EN.pdf - 第42页

4 Service work – HCSII Head Unit 4.14 Replacing the Board Adapter Head Interface C700B 42 Service Manual SIPLACE Head Care Station II 11/2019 4.14 Replacing the Board Adapter Head Interface C700B Parts Fig.56: Board Ad…

100%1 / 68
4 Service work – HCSII Head Unit
4.13 Replacing the LabJack
Service Manual SIPLACE Head Care Station II 11/2019 41
4.13 Replacing the LabJack
Parts
Fig.53: LabJack UE9
LabJack UE9 [03085251‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head Unit" [}20].
Remove the contactors K3 and K4. See 3.5 "Remove the contactors K3 and K4" [}22].
Remove the Head Care Interface with the LabJack. See 4.12 "Replacing the Head Care Inter-
face" [}38].
Removal
Fig.54: Head Care Interface with LabJack
1. Head Care Interface HCSII V2.3
[03149124‑xx]
2. LabJack UE9 [03085251‑xx]
Fig.55: Removal
Open any cable ties where necessary.
You may want to mark the positions of
the relevant connections to make clear
assignment easier later on.
Unplug the cable(1).
Remove the four screws(2) fastening
the Head Care Interface(1) on the Lab-
Jack connectors. Make sure that the
screws are not lost.
Remove the LabJack from the Head
Care Interface.
 CAUTION!
Make sure that you do not damage
the pins.
.
Installation
Follow the removal instructions in reverse order for installation.
Replace any cable ties which you have removed.
4 Service work – HCSII Head Unit
4.14 Replacing the Board Adapter Head Interface C700B
42 Service Manual SIPLACE Head Care Station II 11/2019
4.14 Replacing the Board Adapter Head Interface C700B
Parts
Fig.56: Board Adapter Head Interface
Board Adapter Head Interface
[03085198‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Remove the contactors K3 and K4. See 3.5 "Remove the contactors K3 and K4" [}22].
Remove the compressed air filter. See 4.2 "Replacing the compressed air filter" [}24].
Remove the PCB Base Adapter Twin. See 4.4 "Replacing the Base Adapter Twin /
MHCU" [}26].
Remove the PCB Base Adapter C&P. See 4.6 "Replacing the Base Adapter C&P /
MHCU" [}29].
Remove the Modul Head Interface-C700B. See 4.8 "Replacing the Head Interface-
C700B" [}34].
Remove the Head Care Interface with the LabJack. See 4.12 "Replacing the Head Care Inter-
face" [}38].
4 Service work – HCSII Head Unit
4.14 Replacing the Board Adapter Head Interface C700B
Service Manual SIPLACE Head Care Station II 11/2019 43
Removal
Fig.57: Removal (from behind)
Fig.58: Removal (from front)
Remove the seven screws fastening the
Board Adapter Head Interface(1) on the
frame. Make sure that the screws are not
lost.
Fig.59: Board Adapter Head Interface with Flat ribbon cable
1. Board Adapter Head Interface
2. Flat ribbon cable