4 Service work – HCSII Head Unit
4.10 Replacing the Vision Board
36 Service Manual SIPLACE Head Care Station II 11/2019
4.10 Replacing the Vision Board
Parts
Fig.43: Vision Board Spread Spectrum HCU
Vision Board Spread Spectrum HCU
complete [03067289‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Remove the Modul Head Interface-C700B. See 4.8 "Replacing the Head Interface-
C700B" [}34].
Removal
Fig.44: Removal
Open any cable ties where necessary.
You may want to mark the positions of
the relevant connections to make clear
assignment easier later on.
Unplug the cable J7/X7(3).
Unplug the flat ribbon cable X4.A4(4).
Unplug the two round cables W1/
W2(5) from the Board Adapter Head
Interface.
Remove the tree small screws(2)
fastening the Vision Board(1) on the
frame. Make sure that the screws are
not lost.
Carefully remove the Vision Board.
Fig.45: Vision Board Spread Spectrum HCU
1. Vision Board Spread Spectrum HCU
complete [03067289‑xx]
2. Cables W1/W2
Remove the cables W1/W2(2) from the
Vision Board(1).
Installation
Follow the removal instructions in reverse order for installation.
Replace any cable ties which you have removed.
4 Service work – HCSII Head Unit
4.11 Replacing the Assembly PCB digital
Service Manual SIPLACE Head Care Station II 11/2019 37
4.11 Replacing the Assembly PCB digital
Parts
Fig.46: Assembly PCB digital
Assembly PCB digital [03008825‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Removal
Fig.47: Removal
Remove the four screws(2) fastening
the Assembly PCB digital(1) on the
frame.
Pull the PCB forward(3) out of the
frame.
Unplug the cables.
Installation
Follow the removal instructions in reverse order for installation.
Replace any cable ties which you have removed.
4 Service work – HCSII Head Unit
4.12 Replacing the Head Care Interface
38 Service Manual SIPLACE Head Care Station II 11/2019
4.12 Replacing the Head Care Interface
Parts
Fig.48: Head Care Interface HCSII V2.3
Head Care Interface HCSII V2.3
[03149124‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Remove the contactors K3 and K4. See 3.5 "Remove the contactors K3 and K4" [}22].
Removal
Fig.49: Removal 1
Remove the four screws(1) fastening
the fan(2).
Remove the fan.