00198761-01_SM_Head_Care_Station_II_EN.pdf - 第38页

4 Service work – HCSII Head Unit 4.12 Replacing the Head Care Interface 38 Service Manual SIPLACE Head Care Station II 11/2019 4.12 Replacing the Head Care Interface Parts Fig.48: Head Care Interface HCSII V2.3 ● Head…

100%1 / 68
4 Service work – HCSII Head Unit
4.11 Replacing the Assembly PCB digital
Service Manual SIPLACE Head Care Station II 11/2019 37
4.11 Replacing the Assembly PCB digital
Parts
Fig.46: Assembly PCB digital
Assembly PCB digital [03008825‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Removal
Fig.47: Removal
Remove the four screws(2) fastening
the Assembly PCB digital(1) on the
frame.
Pull the PCB forward(3) out of the
frame.
Unplug the cables.
Installation
Follow the removal instructions in reverse order for installation.
Replace any cable ties which you have removed.
4 Service work – HCSII Head Unit
4.12 Replacing the Head Care Interface
38 Service Manual SIPLACE Head Care Station II 11/2019
4.12 Replacing the Head Care Interface
Parts
Fig.48: Head Care Interface HCSII V2.3
Head Care Interface HCSII V2.3
[03149124‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Remove the contactors K3 and K4. See 3.5 "Remove the contactors K3 and K4" [}22].
Removal
Fig.49: Removal 1
Remove the four screws(1) fastening
the fan(2).
Remove the fan.
4 Service work – HCSII Head Unit
4.12 Replacing the Head Care Interface
Service Manual SIPLACE Head Care Station II 11/2019 39
Fig.50: Removal 2
Open any cable ties where necessary.
You may want to mark the positions of
the relevant connections to make clear
assignment easier later on.
Unplug the cables.
Remove the nine screws(3) fastening
the Head Care Interface(1) on the
frame. Make sure that the screws are
not lost.
Disconnect the grounding connec-
tion(2).
Remove the four distance nuts(4)
fastening the front connections.
Fig.51: Removal 3
Carefully remove the Head Care Inter-
face.