4 Service work – HCSII Head Unit 4.6 Replacing the Base Adapter C&P / MHCU Service Manual SIPLACE Head Care Station II 11/2019 31 Fig.31: Removal 3 ► Carefully move the Base Adapter C&P a bit out (slight rotati…

100%1 / 68
4 Service work – HCSII Head Unit
4.6 Replacing the Base Adapter C&P / MHCU
30 Service Manual SIPLACE Head Care Station II 11/2019
Removal
Open any cable ties where necessary. You may want to mark the positions of the relevant
connections to make clear assignment easier later on.
Fig.29: Removal 1
Unplug the two flat ribbon cables(1)
from the Board adapter(2).
Unplug the round cable X90(3) from
the Board Adapter Head Interface(4)
(main PCB at the back side).
Unplug the black cable X5(5) from the
Modul Head Interface(6).
(Unlock the plug by pressing both
sides.)
Unplug the two flat ribbon cables X1/
X2(7) from the Base Adapter(8).
(The plugs are locked on both sides.)
Fig.30: Removal 2
Remove the two screws(1) fastening
the Base Adapter C&P(3) assembly
bracket on the right side.
Make sure that the screws are not lost.
Loosen the two screws(2) (keyholes,
do not remove the screws!) fastening
the Base Adapter C&P(3) assembly
bracket on the left side.
4 Service work – HCSII Head Unit
4.6 Replacing the Base Adapter C&P / MHCU
Service Manual SIPLACE Head Care Station II 11/2019 31
Fig.31: Removal 3
Carefully move the Base Adapter C&P
a bit out (slight rotating movement).
Unplug the pressure sensor X10(1).
Unthread the round cable X90 and
carefully remove the Base Adapter
C&P from the HCS.
Fig.32: Removal 4
Remove the three screws fastening the
two assembly brackets(1) and(2).
Fig.33: Base Adapter C&P (upper side)
Fig.34: Base Adapter C&P (under side)
1 PCB Base Adapter C&P HCS2.3
[03158917‑xx]
2 MHCU complete compatible
[03090990‑xx]
3 Board Adapter-LP CPP/C&P20-HCSII
[03087843‑xx]
4 Round cable X90
5 Screws fastening the MHCU
Remove the Board Adapter-LP CPP/C&P20-HCSII(3).
4.7 "Replacing the Board Adapter LP CPP/C&P20" [}33].
4 Service work – HCSII Head Unit
4.6 Replacing the Base Adapter C&P / MHCU
32 Service Manual SIPLACE Head Care Station II 11/2019
Replacing/Converting the MHCUs
Remove the screws(5) on the back of the board fastening the MHCU(2) and carefully pull the
MHCU off the base adapter.
CAUTION
Washers/Pins
Make sure not to loose the washers.
Make sure not to damage the pins under the MHCU.
Installation
Fig.35: Installation
Install the two assembly brackets on
the Base Adapter.
Make sure that the assembly brackets
flush with the frame.
To make installation easier, turn the
two screws at the smaller assembly
bracket out until they are barely visible
at the nuts.
Install the Board Adapter-LP CPP/C&P20-HCSII.
4.7 "Replacing the Board Adapter LP CPP/C&P20" [}33].
Insert the Base Adapter C&P into the HCS and thread in the round cable X90.
Plug in the pressure sensor X10.
Thread in the two screws on the left into the keyholes.
Loosely insert the two screws on the right (the front one first).
Push the Base Adapter C&P to the back and fasten the four screws.
Plug in the two flat ribbon cables X1/X2 on the Base Adapter C&P.
(Make sure the plugs are locked on both sides.)
Plug in the black cable X5 at the Modul Head Interface.
Plug in the round cable X90 at the Board Adapter Head Interface (main PCB at the back side).
Plug in the two flat ribbon cables at the Board adapter.
Replace any cable ties which you have removed.