00198761-01_SM_Head_Care_Station_II_EN.pdf - 第18页

2 Spare parts overview 2.4 List of all spare parts 18 Service Manual SIPLACE Head Care Station II 11/2019

100%1 / 68
2 Spare parts overview
2.4 List of all spare parts
Service Manual SIPLACE Head Care Station II 11/2019 17
2.4 List of all spare parts
03152714-xx Safety switch door HCS2.3
03067289-xx VISION BOARD Spread Spectrum HCU cpl.
03050555-xx Vision Hotlink Adapter VHA
03090990-xx MHCU complete compatible
03149124-xx Headcare interface HCS II v2.3
03055072-xx Modul Head Interface C700B
03008825-xx Assembly PCB digital 28
03087843-xx Board Adapter-LP CPP/C&P20-HCS II
03087842-xx Board Adapter-LP C700B-HCSII
03085198-xx Board Adapter Headinteface C700B
03085251-xx LabJack UE9
03158917‑xx PCB-base adapter-C&P-HCS2.3
03158916‑xx PCB-base adapter-Twin-HCS2.3
03087844-xx Board Adapter-LP Twin-HCSII
03079126-xx AC/DC converter FlatPAC 150VDC 400W
03087898-xx AC/DC converter QS10.241 24VDC 10A 240W
03147077-xx AC/DC converter FlatPAC 2 x 40VDC 400W
03120423-xx BoxPC ABP402-A CPU1020E 2xPCI SSD (iBase)
03079973-xx CAN card COM168V2-PCI
03052135-xx Hotlink Interface PCI-A24-K01
03090149-xx PCB Power adjust HCS II cpl.
03148066-xx Cable: Hotlink
03152929-xx Cable connection cable HCS2.3
03159108-xx CAN-BUS: HCS2.3
00375711-xx Connection cable for cold equipment
03148065-xx Cable: USB IO Modul LabJack
03148067-xx Cable: PC GigE
03065971-xx Cable set CPP / B series
03065867-xx Flat cable set C&P20 / B series
03104448-xx VTS board head camera GigE
03152714-xx Safety switch door HCS2.3
03037590-xx Fuse clamp max. 10A type 281-611
03010624-xx Feinsicherung 5x20 / T 1,0A / keramik
03133256-xx Fuse 5x20mm T 6,3A 400VDC
03079075-xx Compressed air filter
Filter element AF40P-060S for compressed air
03003717-xx Cooling air filter element
2 Spare parts overview
2.4 List of all spare parts
18 Service Manual SIPLACE Head Care Station II 11/2019
3 Preparatory work...
3.1 Turn off and disconnect the HCS II
Service Manual SIPLACE Head Care Station II 11/2019 19
3 Preparatory work...
DANGER
Observe safety instructions!
Please observe the safety instructions in this Service Manual and in the HCSII User
Manual for all work!
NOTICE
Observe the detailed circuit diagrams!
For more detailed information refer to the circuit diagrams folder of the HCSII.
Detailed circuit diagrams folder for HCSII [DEEN:00198762‑xx]
3.1 Turn off and disconnect the HCS II
DANGER
Nonobservance may cause injury to personnel and damage to the HCS II!
Before performing any service work on the HCS II, the following steps must be per-
form.
End all verification operations at the HCS II.
Close the SIPLACE Test Bench software.
Shut down the Windows operating system correctly, otherwise problems may occur when
restarting or data may be lost.
Switch off the HCS II at the main switch.
Disconnect the HCS II from the main power supply.
Disconnect the HCS II from the compressed air supply.
3.2 Equipment and tools
Equipment and tools needed to prepare the HCS II Head Unit for service work:
00353832‑xx Allen key set 2 mm, 2.5 mm
00376516-xx Socket wrench set 7 mm
00096290-xx Spanner wrench set 7 mm
00319064-xx Screwdriver Size 1
00318673-xx Side cutter electronic size 110
00096487-xx POINT PLIERS 140mm OVAL
00308458-xx Cable ties B=2.5mm, L=102mm Panduit