JO-116-001_w.pdf - 第104页

4-19 JO-1 16 1 105-001 2. Feeder Measurement T able D4 Models X Y G*-0808* -3.650 -13.000 G*-12160 or more -13.950 -13.000 Align the hole at the fiducial mark position with the center of the crosshair. X/Y Position on Co…

100%1 / 161
4-18
JO-116
1105-001
2. Feeder Measurement
(11) The ducial mark position of the feeder is measured.
The following dialog box appears for three seconds.
Fig. D18
(12) Move the micrometer until the hole at the ducial mark position
is aligned with the center of the crosshair.
4
2
4
2
4 8
12
Direction of Tape Feed
Fiducial Mark Position of
G*-12160 or more
(G*-24320 used in the figure)
Fiducial Mark Position
of G*-0808*
Fig. D19 Position of Fiducial Mark
Note
The ducial mark position is based on the X/Y coordinates of
the computer screen and almost located at the coordinates in
the following table.
4-19
JO-116
1105-001
2. Feeder Measurement
Table D4
Models X Y
G*-0808* -3.650 -13.000
G*-12160 or more -13.950 -13.000
Align the hole at the
fiducial mark position
with the center of the
crosshair.
X/Y Position on
Computer Screen
Fig. D20
(13) Press the [Space] key on the keyboard or the [X/Y Measurement]
button in the window to perform the measurement of the ducial
mark position.
(14) Then, measure the pickup position.
The following dialog box appears for three seconds.
Fig. D21
4-20
JO-116
1105-001
2. Feeder Measurement
(15) Move the micrometer until the hole of the master tape is aligned
with the center of the crosshair.
As for the 8 mm feeder, it must be aligned with the pickup
position on Lane #1.
8 mm Tape Feeder
Lane #1
Lane #2
Fig. D22
Note
The pickup position of each model is based on the X/Y
coordinates of the computer screen and almost located at the
coordinates in the following table.
Move the cursor to the position where the hole of the master
tape can be visible perfectly and perform the measurement.
As for the Y direction, the position varies by 0.5 mm (8 mm
feeder) and 1 mm (12 mm or wider feeder).
Ref
.: The variation occurs because the lane origin offset is set
to "0" (zero) at the measurement.
Table D5
Models X Y
G*-0808*
Lane #1 0.000 0.000
Lane #2 9.500 0.000
G*-12160 4.100 -2.00
G*-24320 -2.600 -6.000
G*-44560 -8.600 -14.000