JO-116-001_w.pdf - 第124页

4-39 JO-1 16 1 105-001 2.2 Operation Procedure for [Measurement T ype 5] (12) The following dialogue box window is displayed. When the offset data calculated based on the teaching data is to be changed, press the [Y es] …

100%1 / 161
4-38
JO-116
1105-001
2.2 Operation Procedure for [Measurement Type 5]
(10) Teach the Lane 2 pick-up hole teaching.
(The positions of the 10 holes are taught successively one by one.)
Fig. D49
(11) When each offset data calculation is completed, the direction Z
offset input window is displayed.
When the pick-up height data is not to be changed, press the [Cancel] button.
When the pick-up height data is to be changed, enter the offset value and press the [OK] button.
Fig. D50
4-39
JO-116
1105-001
2.2 Operation Procedure for [Measurement Type 5]
(12) The following dialogue box window is displayed.
When the offset data calculated based on the teaching data is to
be changed, press the [Yes] button. When it is not to be changed,
press the [No] button.
When the measurement results are written in the feeder, click [Yes].
Fig. D51
(13) When the transfer of the measurement results for writing them in
the feeder, is completed, and the following message "Take out the
feeder" is displayed, remove the feeder.
When the data transmission is completed and this message is
displayed, take out the feeder.
Fig. D52
Notice
During the data transfer to and writing in the feeder, do
not remove the feeder.
4-40
JO-116
1105-001
2.3 Attachment and Detachment of Master Tapes
2.3 Attachment and Detachment of Master Tapes
Reference
Refer to the instruction manual of the tape feeders (for GXH series) for
details.
2.3.1 Attachment of Master Tape(s)
Procedure
(1) While slightly pushing down the suppressor end(s) of the tape
feeder with your nger, press the lower area of the end hook and
lift up the suppressor(s).
(2) Conrm that no foreign substances (chip components, dirt, dust,
etc.) adheres to the chute surfaces and the underside(s) of the
suppressor(s).
Notice
When the master tapes are attached with some foreign
substances being adhered, the suppressors and
master tapes may be deformed, causing an inaccurate
measurement of the pickup position.
(3) Insert the master tape(s) from the end of the tape feeder as shown
in the photos below.
In the case of "8 mm Tape Feeder", insert the master tapes while
slightly pushing down the ends of the suppressors.
Suppressors Suppressor
1) Keep slightly pushing
the suppressors.
Insert the tape up to the first
curving portion of the chute.
2) Insert the tapes up to
the end of the tape
discharge guide.
For 8 mm Tape Feeder For 12/16 mm or wider Tape Feeders
Fig. D53
(4) Attach the master tape(s) to the chute section so that the tape feed
holes can be engaged properly with the sprocket pins.
(5) Conrm that no foreign substances (chip components, dirt, dust,
etc.) are scattered on the master tape(s).
(6) Slowly push down the suppressor(s).