JO-116-001_w.pdf - 第39页

2-2 JO-1 16 1.1 Cable Connection 1 105-001 1.1 Cable Connection Notice Check the seals on the device side and the cable ID plates. Both IDs should match each other when the cables are connected. Seals ID Plates Fig. B2 F…

100%1 / 161
2-1
JO-116
1. Procedure for Jig Installation
CAUTION
At least two people are needed to install the feeder
adjusting jig and the personal computer box.
The jig is very heavy. Be sure not to drop it.
Otherwise, your hands and/or feet will get hurt or
the jig may be damaged.
Carefully handle the jig and the personal computer
box to avoid your nger being caught in the base.
Otherwise, you may receive a hand or foot injury.
Fig. B1 Jig Installation
1. Procedure for Jig Installation
1105-001
2-2
JO-116
1.1 Cable Connection
1105-001
1.1 Cable Connection
Notice
Check the seals on the device side and the cable ID plates. Both
IDs should match each other when the cables are connected.
Seals
ID Plates
Fig. B2
Fig. B3 Connection of Cables for Camera (used to capture the image of the pickup position)
2-3
JO-116
1105-001
1.1 Cable Connection
Schematic Cable Distribution
LIGHT
CN12 CN21
CN11
OUT
1 2 3 4
DC 9V
X21
X12
X11
LIGHT
LIGHT
MUX10F
2Y
MUX10F
1X
PC
CAMERA
CAMERA
X23
X22
X22
MONITOR
X13
From 100-240V
Keyboard
Mouse
Personal
Computer
Adjusting Jig
Electrical Box
Micrometer Unit
(Measured Data
Transfer Unit)
Liquid Crystal Display
Power Supply: 220 V AC
(Note)
Camera Control Unit
(Power Supply for
LED Illumination)
Inside of Box
Inside of Jig
Fig. B4
NOTICE
Before inserting the power plug, be sure to check
the voltage and conrm that it matches the specied
one. Otherwise, the jig unit may break down.
Notice
Cable "X23" must be connected only to the specied port of the
personal computer.
It must be connected to the above-indicated port.
Note
An IEC60320 (old IEC320) type power socket can be connected to the
power outlet.