4022 591 960 62 Operating Manual 02.0 2 FCM Mu ltif lex 53 New Progr am Selection 6. Pla ce a board on th e secon d last boar d position FIGURE 92 7. Pu sh th e guides stri ps ba ck FIGURE 93 Anti collision CLICK! 8. Che…

4022 591 96062 Operating Manual
02.02 FCM Multiflex 52
New Program Selection
3. Select Run-out F9 and hoist in “up” position (F11) (attention: transport
starts moving)
SCREEN 32
4. Open the Run-out cover
FIGURE 90
5. Unlock the guide strips
FIGURE 91

4022 591 96062 Operating Manual
02.02 FCM Multiflex 53
New Program Selection
6. Place a board on the second last board position
FIGURE 92
7. Push the guides strips back
FIGURE 93
Anti collision
CLICK!
8. Check if board is positioned on Run out belt. (board-pitch 360 & 420
mm)
a) If so, then: adjust stopper so that distance between the front side of
the board and the stopper is 0.2 +/- 0.1 mm). Test the stopper by
moving the arm up an down.
b) Else: Turn the stopper arms upwards, by loosening the screws
9. Adjust the anti collision sensor
FIGURE 94
Edge of second
last PCB on X-beam
/
carrier at last index
>80mm
Anti Collision
sensor

4022 591 96062 Operating Manual
02.02 FCM Multiflex 54
New Program Selection
10.Remove board by pushing guide strips back
FIGURE 95
11.Push the Strips back
FIGURE 96
Anti collision
CLICK!
12.Close the run-out cover
FIGURE 97