FK-9F98- 29 XP Series Training Text for Service Engineers Edition 5.0 XP141 – Chapter 6 Proper Data Measurements Page 7 of 26 Fuji Machine Mfg. Co., Ltd. Okazaki SMT Equipment Quality Assurance Dept. 6 – 7 CS Section 14.…

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 6 Proper Data Measurements Page 6 of 26
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
6 – 6 CS Section
8. Inch the Y-axis to the “PrismFront” position (see 6.2 “camera centering” steps 12 and 13).
9. Select [Maintenance A] – [Jog] – [Side1] to activate the side1 prism light source and
display the parts camera live image on the screen.
10. Select the cross hairs and then adjust the position of the resolution measurement jig until
the center dot is in the center of the camera cross hairs:
11. Select [Maintenance A] – [I/O Check] – and turn the following I/Os ON:
I/O Signal
Y00C StroboTrigger ON
Y00D StroboLampA ON
Y00E StroboLampB ON
Y00F StroboCharge ON
12. Select [Program] – [Template Editor] – and then right click on the screen to display a
menu box.
13. Select [Utility] – [Default Setting] and confirm that the default settings are identical to
those shown below, note that the default settings are the same for the parts camera and
the mark camera:
Resolution measurement
glass gauge.
Printed surface
uppermost

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 6 Proper Data Measurements Page 7 of 26
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
6 – 7 CS Section
14. Select [Utility] – [Scale Setting] – [Camera 1] – and click on the resolution measurement
tab:
15. Answer YES to the question “Set Center?” and the resolution measurement will proceed.
16. Answer NO to the question “Do you save calibration data to FD?”
17. To the next question “Save calibration data?” answer YES.
18. Confirm that the resolution results are within the tolerances described below:
Parts camera resolution tolerances
X_Unit 0.0280 ~ 0.032
X_View 38.800 ~ 44.198
Y_Unit 0.0280 ~ 0.032
Y_View 28.985 ~ 33.015
19. The resolution measurement is now complete, right click on the screen and select
[Return].
Resolution
Measurement
1

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 6 Proper Data Measurements Page 8 of 26
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
6 – 8 CS Section
6.6 Adjusting the mark camera
1. Equipment: color sample disc for brightness measurement (Z9531DEPJ1111). Plate Jig
(AJPJ – 0060).
(XC-55) Mark camera setting
1. Set the mark camera settings as outlined in the following table and diagram:
Signal 1N
Gain M
2. If attaching the mark camera unit to the mark camera installation bracket use 0.5N.m
torque.
3. Ensure that the join where the camera lens unit and camera are connected is reinforced
with adhesive.
4. Ensure that adhesive (ThreeBond 1530C) is applied to the hollow bolts that hold the half
mirror in place. Do not over apply adhesive.
Mark camera focus
1. Clamp the plate jig in the main conveyor.
2. Select [Maintenance A] – [Jog] – [Fiducial] – the light comes ON for the mark camera and
the live image is displayed on the screen.
3. Inch the mark camera over the plate jig and set the focus by loosening the mark camera
bracket height adjusting bolts, and then sliding the camera up and down until the
optimum focus height is found.
4. Finally lock the mark camera bracket height adjusting bolts.
Top view of the camera
The orientation of the half-mirror is
not critical to the mark camera
operation; therefore any orientation
is acceptable.