ACT - Accurac y Check Tool / User Manual 09/2015 Edition 29 4.1.1.2 Placement Program Overview for SIPLACE Pro ≥ 11.x Station software v ersion 706.02.S P1 Hotfix 2 or 707. 1.SP1 Hotfix 2 or higher Machine Head Camera No…

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
28
4 Working with the ACT
4.1 Specifying the Placement and Measurement Program from
SIPLACE Pro
NOTICE
Placement program overview
The placement programs available vary according to the machine type and head/camera
configuration.
4.1.1 Selecting the Board (Placement Program)
4.1.1.1 Placement Program Overview for SIPLACE Pro < 11.x
Machine Head
Head
camera
Nozzle Placement program
X-/SX-/DX-series/
CAx with SW 605.xx
C&P20x
2 x C&P20x
SST 23,
SST 41
1004 / 1014
ACT_1xC&P20
(80 x Cerampad)
ACT_2xC&P20
(2 x 80 x Cerampad)
X-/SX-/DX-/
D-series
C&P12-DLM,
CPP
(C&P mode)
2 x C&P12-DLM,
2 x CPP
(C&P mode)
SST 28,
SST 29,
SST 30,
SST 38
904 / 914 /
2004 / 3004
ACT_1xC&P12
(96 x Cerampad)
ACT_2xC&P12
(2 x 96 x Cerampad)
X-/SX-/DX-/
D-series
C&P6-DLM
TH-IC,
P&P-IC
SST 29,
SST 30
SST 33,
SST 36
920
518
ACT_CC02-05
(48 x CC02-05)
X-/SX-/DX-/
D-series
TH-FC,
P&P-FC
SST 25 518
ACT_CC07-500
1)
(48 x CC07-500)
X-/SX-series
CPP
(P&P mode)
SST 33 2057
ACT_CC02-05_CPP
2)
(48 x CC02-05_CPP)
Table 4-1: Assignment of machine, board, head up to SIPLACE Pro < 11.x
1)
Up to software SIPLACE Pro 11.x and the corresponding station software versions, a separate optionally available
glass component CC07-500 (with BGA structure) was used for the SST 25 camera.
As of software SIPLACE Pro 11.x with station software version 706.02.SP1 Hotfix 2 or 707.1.SP1 Hotfix 2 or higher,
the CC02-05 component (with QFP structure) is used for the SST 25 camera (Flip-Chip camera).
If you plan to measure an SST 25 with ACT, we recommend upgrading the software to the versions described below.
2)
Separate board in SIPLACE Pro for measuring the CPP head with an SST 33 stationary camera.

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
29
4.1.1.2 Placement Program Overview for SIPLACE Pro ≥ 11.x
Station software version 706.02.SP1 Hotfix 2 or 707.1.SP1 Hotfix 2 or higher
Machine Head Camera Nozzle Placement program
X-/SX-/DX-series;
X-series S;
CAx
with SW 605.xx
1 x C&P20x
SST 23,
SST 41
1004 / 1014 /
4004
ACT_1xC&P20
(80 x Cerampad)
2 x C&P20x
ACT_2xC&P20
(2 x 80 x Cerampad)
4 x C&P20x
ACT_2xC&P20
(4 x 80 x Cerampad)
CAx with SW
≥707.1.SP1 Hotfix 2, or
706.02.SP1 Hotfix 2;
X-series S micron
≥708.0
1 x C&P20x
SST 41 1004 / 1014
ACT_1xC&P20_HighPrecision
3)
(80 x Cerampad)
2 x C&P20x
ACT_2xC&P20_HighPrecision
3)
(2 x 80 x Cerampad)
CAx,
X-series S micron
≥708.0
1 x CPP
(C&P mode)
SST 30 2004
ACT_1xC&P12_HighPrecision
3)
(96 x Cerampad)
2 x CPP (C&P mode)
ACT_2xC&P12_HighPrecision
3)
(2 x 96 x Cerampad)
X-/SX-/DX-/D-series;
X-series S;
E by SIPLACE
4)
1 x C&P12-DLM,
1 x CPP
(C&P mode)
SST 28,
SST 29,
SST 30,
SST 38
904 / 914;
2004 / 3004
ACT_1xC&P12
(96 x Cerampad)
2 x C&P12-DLM,
2 x CPP
(C&P mode)
ACT_2xC&P12
(2 x 96 x Cerampad)
D-/X-series and
CAx
with SW 605.xx;
E by SIPLACE
4)
C&P6
SST 29,
SST 30
920 / 3020
ACT_CC02-05
(48 x CC02-05)
X-/SX-/DX-/D-series;
X-series S;
E by SIPLACE
4)
TH-IC,
P&P-IC,
CPP (P&P mode)
SST 33,
SST 36
518 / 2057
ACT_CC02-05_PP
2)
(48 x CC02-05)
X-/SX-/DX-/D-series;
X-series S;
TH-IC,
P&P-IC,
CPP
(P&P mode)
SST 33,
SST 36
518 / 2057
ACT_CC02-05_CPP_TH
5)
(48 x CC02-05)
X-/SX-/DX-/D-series;
X-series S;
E by SIPLACE
4)
TH-IC,
P&P-IC
SST 25 518
ACT_CC02-05_FC
1)
(48 x CC02-05)
E by SIPLACE
4)
1 x C&P14
SST 23,
SST 41
4004
ACT_1xC&P14
(112 x Cerampad)
Table 4-2: Assignment of machine, board, head as of SIPLACE Pro 11.x
1)
As of software SIPLACE Pro 11.x with station software version 706.02.SP1 Hotfix 2 or 707.1.SP1 Hotfix 2 or higher,
the CC02-05 component (with QFP structure) is used for the SST 25 camera (Flip-Chip camera).
The CC07-500 glass component (with BGA structure) is not supported anymore.
If the CC07-500 component is already available and still to be used for measuring the SST 25 camera, the
corresponding board with its component and component shape data and the tables can be selectively imported from
the *.sipro files of the SIPLACE Pro 9 version. This data can be obtained from the Software License Portal or via the
hotline.
2)
As of software SIPLACE Pro 11.x with station software version 706.02.SP1 Hotfix 2 or 707.1.SP1 Hotfix 2 or higher.
From this version, a separate board description is available for all Pick & Place heads in which the CPP head has now
been integrated for the P&P mode.
3)
For machines requiring higher precision, such as CA machines and X S Micron, separate high precision programs with
high precision Cerampads are available for measuring the C&P20 heads. As of the software versions mentioned
above, it is possible to enable a Precision parameter in the component shape description.
4)
Machine type E by SIPLACE, as of station software version 708.0.
5)
For compatibility with older station software versions.
If SIPLACE Pro has been updated without updating the station software, the machine verification of CPP heads in P&P
mode can be performed anyway with this program.

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
30
4.1.2 Scheduling the Boards
► Select a suiting placement program for your head configuration from the pre-configured boards
(with the aid of Table 4-1 or Table 4-2).
► Specify a job (recipe) in SIPLACE Pro Line Control and send it to the line (download).
NOTICE
Placement machines with dual conveyors
When using a dual conveyor, the ACT should be run with both conveyor lanes.
4.1.2.1 Troubleshooting: Accessibility for Various Machine / Head Configurations
SIPLACE SX4 and DX4 machines:
NOTICE
In order to access the fiducials, the ACT measuring plate has to be placed rotated by
180° in SIPLACE SX4 and DX4 machines.
Thus, if an ACT placement program is defined for a SIPLACE SX4 or DX4 machine, the orientation
(position) of the board has to be adapted to 180° in the created recipe.
Figure 4-1: Rotating board orientation by 180°on SX4, DX4