00196351-06_UM_ACT_DE_EN.pdf - 第143页
ACT - Accurac y Check Tool / User Manual 09/2015 Edition 53 Figure 4-30: Dialog box operating mode switchover to SIPLACE Pr o at the station (example SIPLACE D1) ► Press the START button on t he machine. The reference ru…

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
52
Figure 4-28: Dialog box: Access level (example SIPLACE D1)
► Enable the Servicetechniker (Service) access level and confirm your entry with OK.
If a password has been defined, a dialog box will open for you to enter this password.
► Enter the password and confirm with OK.
► Select the Optionen − Betriebsart... (Options − Control mode...) menu items.
Figure 4-29: Basic view of user interface for SC program (example SIPLACE D1)
This opens the Betriebsart (Control mode) dialog box.
► Select SIPLACE Pro and confirm the setting with OK.

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
53
Figure 4-30: Dialog box operating mode switchover to SIPLACE Pro at the station (example SIPLACE D1)
► Press the START button on the machine.
The reference run is carried out.
► Send the recipe / job to the station with the relevant setup and the ACT placement program.
► From the Optionen (Options) menu, select Modus ACT (ACT mode).
The ACT dialog box opens and the machine will automatically switch to Stand Alone mode.
Figure 4-31: Basic view of user interface for SC program (example SIPLACE D1)
After setting ACT mode, an icon will be displayed for ACT.

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
54
Figure 4-32: Dialog box after setting ACT mode. Display: ACT icon
The Leiterplatteneingabe (Enter PCB) dialog box is opened (Figure 4-33).
► Select the ACT board.
Figure 4-33: Dialog box: Enter PCB (example SIPLACE D1)
The Leiterplatteneingabe (Enter PCB) dialog box is opened (Figure 4-34).
► Select the ACT board.
► Select the conveyor lane.
► Confirm your entry with OK.