ACT - Accurac y Check Tool / User Manual 09/2015 Edition 33 If you use the "Adapt er 50 mm TWIN" [03085310 - 01] in the out ermost panel you have to extend the board by 50 mm in SIPLACE Pro Desk! ► For this, en…

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
32
► In order to further increase the statistical reliability of the measurement result and at the same
time make sure that each segment meets these requirements, you can check each segment
individually.
► For this, omit one of the segments in the Nozzle configuration tab of the Setup Editor in
SIPLACE Pro so that only one segment places all 48 components.
Figure 4-3: Omitting segment
Twin Head in Placement Area 1:
For machines with Twin Head in Placement Area 1 (i.e. gantry 1 and / or 4) you can use the
following adapter to ensure the accessibility of segment 2 when placing on the plate. The adapter is
inserted at the front of the plate so that the plate moves about 50 mm backwards in the direction of
the input belt.
Adapter 50 mm TWIN [03085310-01]
Figure 4-4: Adapter 50 mm TWIN

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
33
If you use the "Adapter 50 mm TWIN" [03085310-01] in the outermost panel you have to extend
the board by 50 mm in SIPLACE Pro Desk!
► For this, enter 390 mm instead of 340 mm for the length in the board description you want to
use (ACT_CC02-05_CPP_TH).
Figure 4-5: Extending the board
4.1.3 Creating a Setup (Assigning Tables)
► Copy an existing setup of your line.
► Replace the tables by using the prepared tables for ACT that you have already imported. (see
section 3.2.5).
Tables are available for each possible machine.
(1)
(2)
(3)
(4)
(5)
Key:
(1) S-tables with setup (4) X-tables with setup
(2) Empty S-tables (5) Empty X-tables
(3) TC = Tray Changer (WPC/MTC)

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
34
Available S-tables:
Available X-tables:
Available tables (setups) for WPC/MTC: