00196351-06_UM_ACT_DE_EN.pdf - 第134页
ACT - Accurac y Check Tool / User Manual 09/2015 Edition 44 Figure 4-17: Intervention guard c ompletely mounted Figure 4-18: Tray set up with i ntervention guard NOTICE The gaps still remaini ng to the left and right of …

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
43
4.2.1.1 Intervention Guard
WARNING
To ensure operational safety, all feeder modules must be set up on all tracks. If
insufficient feeder modules are available, an intervention guard ("dummy feeder") must
be set up on unoccupied tracks.
For S tables: 1 track 00116961-xx
6-10 tracks 00116962-xx
11-20 tracks 00116963-xx
For X tables: 1 track 00141226-xx
If the ACT waffle pack tray is used, the cover plate of the magazine is to be combined
with part "03073250-01 ACT intervention guard, complete" using the knurled screw to
form a single unit (see Figure 4-17
) and is only permitted to be set up in the machine in
this form (Figure 4-18).
Figure 4-16: Component parts of the intervention guard

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
44
Figure 4-17: Intervention guard completely mounted
Figure 4-18: Tray set up with intervention guard
NOTICE
The gaps still remaining to the left and right of the tray must be closed off with the
dummy feeders described above so that full protection against intervention in the
machine from the outside is ensured.

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
45
4.2.2 Setting Up Components in a WPC/MTC
► Move the tray changer into the refill position.
► Remove an empty plate (waffle pack tray carrier) from the tower.
► Fasten the tray on the plate as displayed below.
► Push the plate into the corresponding level according to the specified setup.
Figure 4-19: Fastening tray on plate
NOTICE
The tray has a cutout at the bottom of the long side.
► Therefore, use the magnets for fastening the tray so that the high plate side of the
magnet faces the tray and not the rubber side.