00193802-01.pdf - 第155页
User Manual SIPLAC E CF 6 Component han dling Software version SR.101.xx 06/2003 US Edition 6.4 Component trolley 155 6.4 Component trolley 6.4.1 Structure The com ponent tr olley cons ists esse ntially of a chassi s, a …

6 Component handling User Manual SIPLACE CF
6.3 Setting up the feeders Software version SR.101.xx 06/2003 US Edition
154
Æ Carry out a refill check if necessary.
Æ Continue placement.
Fig. 6.3 - 1 Inserting 30 or 45 mm wide feeders on the component feeder table
6
(1) Feeder, 30 mm wide
(2) Feeder, 45 mm wide
(3) Feeder, 30 mm wide
(4) Centering ball
(5) Component feeder table

User Manual SIPLACE CF 6 Component handling
Software version SR.101.xx 06/2003 US Edition 6.4 Component trolley
155
6.4 Component trolley
6.4.1 Structure
The component trolley consists essentially of a chassis, a component feeder table on which the
feeder is mounted, a communication unit, a tape container and a waste container. Docking the
component trolley in or out is described in Section 5.9
, page 130 onwards.
Fig. 6.4 - 1 Component trolley
(1) Component trolley
(2) Communication unit
(3) Control button for raising the component feeder table
(4) Component feeder table
(5) Handle for locking and lowering the component feeder table
(6) Tape container
(7) Waste tape container
NOTE ON OPERATIONAL SAFETY 6
All component trolleys must be docked on the machine in order to operate it. If they are not, the
machine stays in emergency stop status. The placement process is interrupted. 6

6 Component handling User Manual SIPLACE CF
6.4 Component trolley Software version SR.101.xx 06/2003 US Edition
156
6.4.2 Tape container
Reels up to 19" in diameter may be used. Insert the spindles into the dividing plates as shown in
Fig. 6.5 - 2
.
PLEASE NOTE 6
We recommend that you use spindles if the tape reel diameter exceeds 7". This will ensure that
the feeders operate reliably. 6
Fig. 6.4 - 2 Component trolley with tape container
(1) Component trolley
(2) Spindle
(3) Dividing plate
(4) Tape container
6.4.3 Compressed air supply for bulk case feeder
Bulkcase feeders require compressed air to operate. We therefore offer a compressed air supply
for bulkcase feeders as an optional extra.