00193802-01.pdf - 第52页
2 Operational safety User Manual SIPLACE CF 2.5 Safety equipment Sof tware version SR.101.xx 06/2003 US E dition 52 Fig. 2.5 - 5 Sa fety circuits 2 2 Active K1 *) yes K2 *) yes Vo l t a g e Y axis 155 V X axis 155 V S ta…
User Manual SIPLACE CF 2 Operational safety
Software version SR.101.xx 06/2003 US Edition 2.5 Safety equipment
51
K1 or K2 is triggered if any of these functions fail. The mains voltage to the heavy current trans-
former that supplies the gantry axis motors will be interrupted. The voltage to the star-type motor
for the Collect&Place head is reduced from 70 V to 10V. The DP and DR axes of the placement
heads continue to be supplied with 30V. The next diagram illustrates the various statuses of K1
and K2 and their effects on the axes and the PCB conveyor components.

2 Operational safety User Manual SIPLACE CF
2.5 Safety equipment Software version SR.101.xx 06/2003 US Edition
52
Fig. 2.5 - 5 Safety circuits
2
2
Active
K1 *) yes
K2 *) yes
Voltage
Y axis 155 V
X axis 155 V
Star axis 70 V
DP axis 30 V
Z axis 30 V
Active
PCB conveyor yes
Lifting table yes
PCB clamping yes
Width adjustment yes
PCB stopper yes
Used tape cutter yes
2
Active
K1 *) no
K2 *) yes
Voltage
Y axis 0 V
X axis 0 V
Star axis 10 V
DP axis 30 V
Z axis 30 V
Active
PCB conveyor yes
Lifting table no
PCB clamping no
Width adjustment yes
PCB stopper no
Used tape cutter no
2
Active
K1 *) no
K2 *) no
Voltage
Y axis 0 V
X axis 0 V
Star axis 10 V
DP axis 30 V
Z axis 30 V
Active
PCB conveyor no
Lifting table no
PCB clamping no
Width adjustment no
PCB stopper no
Used tape cutter no
2
Start button pressed?
2
EMERGENCY STOP
button pressed?
Compressed air
min. 0.5 MPa
(5.0 bar)?
No
Protective cover open ?
No
Component
trolley safety circuit
interrupted?
Yes
No
No
Yes
Yes
No
Yes
Yes
Key switch
closed (positionI)?
*) K1, K2 protective contactor combination

User Manual SIPLACE CF 2 Operational safety
Software version SR.101.xx 06/2003 US Edition 2.5 Safety equipment
53
2.5.5 Guard on the component table locations
WARNING 2
All locations must be equipped with feeders in order to guarantee operational reliability. If there
are not enough feeders available, a guard ("dummy feeder") must be fitted in place of the feeder.2
2
Fig. 2.5 - 6 Guard
2
(1) Guard for 1 location part no. 00116961-01
(2) Guard for 6 to 10 locations part no. 00116962-01
(3) Guard for 11 to 20 locations part no. 00116963-01