User Manual SIPLAC E CF 3 Technical data Software version SR.101.xx 06/2003 US Edition 3.10 Vision modules 97 3.10.3 Fine-pitch ca mera for th e Pick&Pla ce head 3 Fig. 3.10 - 2 Fine-pitch camera for the Pick& Pl…

3 Technical data User Manual SIPLACE CF
3.10 Vision modules Software version SR.101.xx 06/2003 US Edition
96
3.10.2 Component camera (standard camera) on the 6-segment Collect&Place
head
3.10.2.1 Structure
3
Fig. 3.10 - 1 Component camera (standard camera) on the 6-segment Collect&Place head
3
(1) Component camera, lens and illumination
(2) Camera amplifier
(3) Illumination control
3.10.2.2 Technical data
3
Max. component dimensions 0.6 mm x 0.3 mm to 18.7 mm x 18.7 mm
Range of components 0201 to PLCC44
including BGA, µBGA, flip-chip, TSOP, QFP
PLCC, SO to SO32, DRAM
Min. lead pitch 0.5 mm
Min. bump pitch 0.35 mm
Min. ball/bump diameter 0.2 mm
Field of vision 24 mm x 24 mm
Method of illumination Front-lighting (3 levels, programable as required)

User Manual SIPLACE CF 3 Technical data
Software version SR.101.xx 06/2003 US Edition 3.10 Vision modules
97
3.10.3 Fine-pitch camera for the Pick&Place head
3
Fig. 3.10 - 2 Fine-pitch camera for the Pick&Place head
(1) Fine-pitch camera for the Pick&Place head
3.10.3.1 Technical data
3
Max. component dimensions 32 mm x 32 mm (single measurement)
55 mm x 55 mm (multiple measurement)
(larger components possible upon request)
Range of components PLCC, LCCC, QFP, SO, BGA, flip-chip,
components with connectors up to 55 mm x 55 mm
(J leads and gull-wings, balls, bumps)
Min. lead pitch 0.4 mm
Field of vision 38 mm x 38 mm
Method of illumination Front-lighting (3 levels, programable as required)

3 Technical data User Manual SIPLACE CF
3.10 Vision modules Software version SR.101.xx 06/2003 US Edition
98
3.10.4 PCB camera (standard camera)
3.10.4.1 Structure
3
Fig. 3.10 - 3 PCB camera
3
(1) PCB camera, lens and illumination
(2) Camera amplifier
3.10.4.2 Technical data - PCB camera
3
Fiducials Up to 3 per placement program
Library size Up to 255 fiducial types - system fiducials 249
Image processing Geometric alignment
Method of illumination Front-lighting
Recognition time per fiducial/bad fiducial 0.4 s
Field of vision 5.7 mm x 5.7 mm