00193802-01.pdf - 第81页

User Manual SIPLAC E CF 3 Technical data Software version SR.101.xx 06/2003 US Edition 3.6 Controls 81 3 Fig. 3.6 - 2 Overview of the modules - controls - part 2 3 (1) Operat or panel, output c onveyo r (2) Emerge ncy st…

100%1 / 188
3 Technical data User Manual SIPLACE CF
3.6 Controls Software version SR.101.xx 06/2003 US Edition
80
3.6 Controls
3.6.1 Position of the controls
3
Fig. 3.6 - 1 Overview of the modules - controls - part 1
(1) Operator panel, input conveyor
(2) Emergency stop button
(3) Start button (white)
(4) Stop button (black)
(5) Main power switch
(6) Keyboard with trackball
(7) Monitor
(8) Indicator lamps
User Manual SIPLACE CF 3 Technical data
Software version SR.101.xx 06/2003 US Edition 3.6 Controls
81
3
Fig. 3.6 - 2 Overview of the modules - controls - part 2
3
(1) Operator panel, output conveyor
(2) Emergency stop button
(3) Start button (white)
(4) Stop button (black)
(5) Component counter
(6) Key-operated switch
(7) Component barcode reader
(8) Station computer
3 Technical data User Manual SIPLACE CF
3.6 Controls Software version SR.101.xx 06/2003 US Edition
82
3.6.2 Description
All the controls can be reached by a 1.60 m tall person.
Main power switch
The main power switch is used to switch the power supply to the placement machine on and off.
RISK OF DEATH
Some parts inside the placement system carry potentially lethal voltages - even when switched
off at the main switch. 3
Key switch
In normal mode, the key switch is set to "0". The key should be removed and kept in a safe place.
It must only be turned to position "I" (set-up mode) by authorized personnel, and then only for
certain maintenance and servicing work.
Stop button
This button is used to stop the placement machine.
Start button
This button starts the placement machine after it has been switched on or after faults have been
eliminated.
Emergency stop button
The emergency stop button latches in the ON position when pressed. The power supply to the
gantry axes, the components changeover tables, conveyors, and used tape cutters is interrupted
and the voltage supplied to the star axes of the placement heads is reduced. Turn the button to
release it.
Component counter
The component counter displays the number of components processed.
Station computer, monitor and keyboard
The monitor and keyboard are mounted on a rotatable bracket. The station computer is a desk-
top model. It has a Pentium processor and runs the WINDOWS XP operating system. The
SIPLACE graphical user interface, which is based on the Windows standard, is used to operate
and monitor the placement system. A 15" color monitor with a resolution of 1024 x 768 pixels