2 Operational safety User Manual SIPLACE CF 2.6 Residual voltages and discharge time s in the placement machine Software version SR.101.x x 06/2003 US Edition 54 2.6 Residual volt a ges and discharge times in the placeme…

User Manual SIPLACE CF 2 Operational safety
Software version SR.101.xx 06/2003 US Edition 2.5 Safety equipment
53
2.5.5 Guard on the component table locations
WARNING 2
All locations must be equipped with feeders in order to guarantee operational reliability. If there
are not enough feeders available, a guard ("dummy feeder") must be fitted in place of the feeder.2
2
Fig. 2.5 - 6 Guard
2
(1) Guard for 1 location part no. 00116961-01
(2) Guard for 6 to 10 locations part no. 00116962-01
(3) Guard for 11 to 20 locations part no. 00116963-01

2 Operational safety User Manual SIPLACE CF
2.6 Residual voltages and discharge times in the placement machine Software version SR.101.xx 06/2003 US Edition
54
2.6 Residual voltages and discharge times in the
placement machine
When the emergency stop button is pressed or the placement system is switched off, the electro-
lytic capacitors quickly discharge to safe residual voltage levels via switched resistors on the dis-
charge board (00308443-xx).
The voltages can be tapped off at test sockets 001 - 009 on the voltmeter unit in the servo unit.
WARNING 2
Automatic placement systems from the SIPLACE family are powered with 3 x 400 VAC (3 x 208
VAC for the U.S.A. version) ± 5 %, 50/60 Hz main power voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power switch.
Death, serious injury or considerable damage may result if these automatic placement systems
are handled incorrectly. Always follow the applicable accident prevention and DIN regulations
(particularly EN 60204, part 1).
The guard over the servo unit must ONLY be opened by appropriately qualified and trained per-
sonnel. 2
2
Fig. 2.6 - 1 Test sockets on the voltage measuring unit in the servo unit
GND
007
001 002 003 004 005 006
008 009
70VDC/
10VDC
30VDC 24VDC 12VDC 5VDC
70VDC
155VDC/0VDC
30VDC
unswitched
switched

User Manual SIPLACE CF 2 Operational safety
Software version SR.101.xx 06/2003 US Edition 2.6 Residual voltages and discharge times in the placement machine
55
2.6.1 Operating voltages, residual voltages and discharge times after pressing
the emergency stop button
2
2.6.2 Residual voltages and discharge times after switching off at the main switch
2
CAUTION
To avoid losing data, evaluate the following criteria before switching off your automatic placement
system (apart from in emergencies):
– Has the placement system finished transmitting machine, setup and panel data?
– Has the placement system finished processing the PCB?
– Has the placement system completed the run-up phase?
– Has the Windows XP operating system been shut down correctly? 2
Test socket 00X
measured at 007
(GND)
Voltage in normal
mode
Residual
voltage after
EMERG. STOP
Discharge times of
electrolytic capacitors at
12 VDC
001 70 VDC 10 VDC < 2 sec
002 30 VDC 30 VDC –
003 30 VDC < 12 VDC < 2 sec
004 24 VDC 24 VDC –
005 12 VDC 12 VDC –
006 5 VDC 5 VDC –
008 70 VDC 10 VDC < 2 sec
009 155 VDC 10 VDC < 1 sec
Tab. 2.6 - 1 Operating voltages, residual voltages and discharge times after pressing the emergency stop button
Test socket 00X
measured at 007 (GND)
Residual voltage when
main power switch is off
Discharge times of electrol.
capacitors at 12 VDC
001 < 12 VDC < 2 sec
002 < 12 VDC < 2 sec
003 < 12 VDC < 2 sec
004 0 VDC –
005 0 VDC –
006 0 VDC –
008 < 12 VDC < 2 sec
009 < 12 VDC < 1 sec
Tab. 2.6 - 2 Residual voltages and discharge times after switching off at the main switch