3OM-1208-011_w.pdf - 第152页
3-65 AIVEDT -ID 3.1 Single Pattern (Global Recognition Enabled) (1) Information on Pattern Program Creation • PCB size 250 mm 1.6 mm 330 mm PCB PCB Flow Direction Fig. 3C50 • Packaged Posture and IDs of Components [3] [2…

3-64
AIVEDT-ID
0606-009
3. Example of Pattern Program Creation
3. Example of Pattern Program Creation
Described on the following pages are the examples of pattern programs to be
created.
Notice
The examples are based on "Front Right" (Placement Coordinate
Reference Point).
Create the pattern programs according to the placement coordinate
reference point of each system.
•
Single Pattern
(Global Recognition Enabled)
•
Repetitive Patterns
(Image Recognition Enabled)
•
Multi-Model Repetitive Patterns
•
Data for Polar Coordinate Conversion Function
•
Placement Data for Priority Sorting Function
Note
Marks in "Required Data"
: This means that you must refer to the description of the pattern
program data and create the data correctly.
×
: This means that you must refer to the description of the pattern
program data and set "Disable" for the pertinent functions.

3-65
AIVEDT-ID
3.1 Single Pattern (Global Recognition Enabled)
(1) Information on Pattern Program Creation
•
PCB size
250 mm
1.6 mm
330 mm
PCB
PCB Flow Direction
Fig. 3C50
•
Packaged Posture and IDs of Components
[3]
[2]
[1]
User Direction of Feed
No. Component IDs
[1] TANA3216C0HIT
[2] TR2012-3B0HIT-L2
[3] S0P008-B02SAN32E
Fig. 3C51
•
Fiducial Mark
1.0 mm
Fig. 3C52
0606-009
3.1 Single Pattern (Global Recognition Enabled)

3-66
AIVEDT-ID
•
Placement Coordinates, Angles, and Fiducial Mark Coordinates
X3
Y3
X2
Y2
X1
FX1
Y1
FY1
FY2
FX2
Placement Coordinate
Reference
Fiducial Mark
Fiducial Mark
Fig. 3C53
•
List of Required Data
Table 3C4
Pattern Program Required Data
Operation Data PCB Data
PEC Recognition Data
PEC Recognition Mark Data
Setup Data Note (a)
Placement
Head/Nozzle Data
Heads 1 through 4
Placement Feeder
Location Data
Feeder Bases #1 through #4
Placement Data U01 P-data P-data
Unit Control Note (b)
Unit PCB Fiducial ×
O-data
×
Placement Data Un P-data P-data ×
Unit Control ×
Unit PCB Fiducial ×
O-data ×
Note
(a) Create this data for automatic conveyor width adjustment.
(b) Specify these parameters (data) according to the situational changes.
0606-009
3.1 Single Pattern (Global Recognition Enabled)