2 STINGER, A GUIDE TO ADHESIVE DOT DISPENSING 2.4 PRODUCT CHANGEOVER GUIDE TO ADHESIVE DOT DISPENSING STINGER 03/2021 49 2.4.3.1 Replacing the Wiper Pad; Removing the Waste Container W ARNING BOARD CLAMPS. EXTREME CARE M…

100%1 / 64
2 STINGER, A GUIDE TO ADHESIVE DOT DISPENSING
2.4 PRODUCT CHANGEOVER
48 GUIDE TO ADHESIVE DOT DISPENSING STINGER 03/2021
There are two process types for purging - Standard Purge Process and Automatic Purge Process.
The standard process provides the facility to dispense material, directly onto the calibrated test
product, for an indefinite amount of time. This purges air pockets from the dispense head, or it is
used to empty a dispense head of material. The automatic process allows the purge to be carried
out at a purge station. The purge station also has a nozzle wipe facility.
The automatic purge process is used when a complete system purge is required; either at the start
or at the end of a production batch. As this process requires a large volume of material to be
purged, a purge station is used to collect it.
Purge station consumable monitoring is turned on in Maintenance\Machine Setup\Options
\Stinger Options\Stinger Consumable Monitoring.
When the pot is full an action panel is displayed reminding the user to replenish the pot.
NOTE
In product changeover, where hardware has been replaced, the laser unit needs to be recalibrated.
It is advised to carry out the manual calibration of Stinger heights, see appendix, prior to performing
the automatic calibration.
2 STINGER, A GUIDE TO ADHESIVE DOT DISPENSING
2.4 PRODUCT CHANGEOVER
GUIDE TO ADHESIVE DOT DISPENSING STINGER 03/2021 49
2.4.3.1 Replacing the Wiper Pad; Removing the Waste Container
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
MANDATORY
TOXIC SUBSTANCES MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC SUBSTANCES MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
The lid is fixed with two captive shoulder screws, when in the locked position it engages a hook
mechanism. Underneath the lid there are two ball bearings that engage a dimple in the lid to
provide the lock. The lid can be opened by swivelling it as shown by the arrow in the graphic.
1
2
4
5
6
3
1 Wiper Pad 4 Waste Container
2 Lid (as viewed from underside) 5 Captive Screw
3 Replace 6 Hook Screw
1. Swivel the lid in the rotate direction shown, inwards away from the board clamps.
2. The waste container can now be removed, emptied, cleaned and replaced.
3. Remove the used wiper pad and replace with new.
4. Rotate the lid and wiper assembly back into position until it locks in place.
NOTE
The unit can be fitted to either the right hand or the left hand side of the rising table. The lid is de-
signed such that it swivels in towards the centre of the machine. The lid can be fitted correctly for
either left hand or right hand usage; simply fix it to the opposite screw locations to those shown, i.e.
the hook screw becomes the captive screw.
2 STINGER, A GUIDE TO ADHESIVE DOT DISPENSING
2.4 PRODUCT CHANGEOVER
50 GUIDE TO ADHESIVE DOT DISPENSING STINGER 03/2021
2.4.3.2 Calibrated Test Product Page
1. For calibrated test product purging, select Open Cover Commands. Open the front printhead
cover.
2. Selecting Start Purge starts the purge routine. Adhesive is delivered onto the centre of the
boards’ upper surface until the Stop Purge
button is selected.
3. Purging should be monitored to ensure that the adhesive delivery is flowing without being
spurious or spluttering. Any signs of inconsistency are likely to be due to air pockets in the de-
livery mechanism. Provided the assembly has been set up correctly this should be almost
negligible.