141-400-57-probestationaccessoriescatalog.pdf_-_141-400-probestationaccessoriescatalog_1.pdf.pdf - 第117页

PN 141-400 www.formfactor.com Probe Card Holders • 10 1 Revision 57, February, 2023 Probe Station A ccessories 122 -4 37 — Edg e Conn ec t or Kit Pr ob e Car d Hold er s Feat ur es • Edg e connector kit for Summit 1 14 m…

100%1 / 169
PN 141-400 www.formfactor.com Probe Card Holders 100
Revision 57, February, 2023 Probe Station Accessories
SUMMIT/S300
110-367 Probe Card Holder for 6 in Round Cards
Features
Probe card holder for 152 mm (6
in) round cards
Mounts on Summit 12000 and
S300
Specifications
152 mm (6 in) round probe card holder (for Pyramid probe cards)
Theta adjustment
No Z (height) adjustment (probe station Z is required)
Compatibility
Summit, S300
114-338 High Force Probe Card Holder
Features
Easy to use probe card
clamp
Screw removal is not
required to change
similar types of probe
cards
No tools requir ed to
clamp the probe card in place
Back pivoting edge connector for easy mating of edge card
connector
Sup port for 114 mm (4.5 in) rectangular probe cards up to 289 mm
(11.375 in) long
Stable 3-point planarization adjustment
Easy probe card height setting (three incremental settings)
Probe card height adjustment accommodates FormFactor low
leakage probe ca rds and other probe cards
Theta micrometer control located in front of the HF-PCH
Includes 48 pin and 70 pin edge connectors
Specifications
Maximum probe needle force: 20 kg (44 lb) (2,000 needles)
Temperature range:
System with MicroChamber -55ºC to 300ºC (-67ºF to 572ºF)
System without Micr oChamber ambient t o 300ºC (572ºF)
Theta ran ge: ±3º
Maximum planarization height compensation: 1.27 mm (0.050 in)
Probe card maximums:
W = 11.4 cm ±3 mm (4.5 in ±.012 in)
L = 15.25 cm 28.9 cm (6 in 11.375 in)
Thickness = 0.15 cm 0.32 cm (0.060 in 0.125 in)
Compatibility
Summit, S300
115-418 High Force Pro be Card Holder for
MicroChamber
Features
Easy to use
probe card
clamp
Screw
removal is not
required to
change
similar types
of probe
cards
No tools required to clamp the probe card in place
Back p ivoting edge connector for easy mating of edge ca rd
connector
Support for 114 mm (4.5 in) rectangular probe cards up to 289 mm
(11.375 in) long
Maintains a dark and dry EMI-RFI shielded environment
(MicroChamber version o nly)
Stable 3-point planarization adjustment
Easy p robe card height setting (three incremental settings)
Probe card height adjustment accommodates FormFactor low
leakage probe cards and ot her probe cards
Theta micrometer control located in front of the HF-PCH
Includes 48 pin and 70 pin ed ge connectors
Specifications
Maximum probe needle force: 20 kg (44 lb) (2,000 needles)
Temperature range:
System with MicroChamber -55ºC to 300ºC (-67ºF t o 572ºF)
System without MicroChamber ambient to 300ºC (572ºF)
Theta range: ±3º
Maximum planarization height compensation: 1.27 mm (0.050 in)
Probe card maximums:
W = 11.4 cm ±3 mm (4.5 in ±.012 in)
L = 15.25 cm 28.9 cm (6 in 11.375 in)
Thickness = 0.15 cm 0.32 cm (0.060 in 0.125 in)
Compatibility
Summit
PN 141-400 www.formfactor.com Probe Card Holders 101
Revision 57, February, 2023 Probe Station Accessories
122-437 Edge Connector Kit Probe Card Holders
Features
Edg e connector kit for Summit
114 mm (4.5 in) probe card
holders
Sup port both 48 and 70 pin
standard edge connectors
Pivots for easy loading of
probe card
Kit Contents
Edg e connector mount
48 pin edge connector
70 pin edge connector
Compatibility
Summit, S300
120-935 Low-Profile Probe Card Holder for Summit
(Non-MicroChamber)
Features
Sup port for 114
mm (4.5 in)
rectangular
probe cards up to
289 mm (11.375
in) long
Simultaneous use of a probe card and multiple po sitioners/DC
probe needles
DC probe needles can be used with the LP-PCH left in place
Easy to use probe card clamp
Screw removal is not required to change similar types of probe
cards
No tools requir ed to clamp the probe card in p lace
Back pivoting edge connector for easy mating of edge card
connector
Adjustable edge connector mounting brackets to support long
probe cards
Ena bles use of DCP probes without probe card in place
Accurate, front-located theta ad justment wheel
Stable 3-point planarization adjustment
Probe card height adjustment accommodates variability in probe
card needle depth
Probe card height adjustment accommodates FormFactor low
leakage probe ca rds and other probe cards
Includes 48 pin and 70 pin edge connectors
Specifications
Maximum probe needle force: 1 kg (2.2 lb) (100 needles)
Theta range ±
Maximum planarization height compensation: 0.762 mm (0.030 in)
Probe card maximums:
W = 11.4 cm ±3 mm (4.5 in ±.012 in)
L = 15.25 cm 28.9 cm (6 in 11.375 in)
Thickness = 0.15 cm 0.32 cm (0.060 in 0.125 in)
Compatibility
Summit
124-118 Low-Profile Probe Card Holder for Summit
Stations with MicroChamber
Features
Support for 114 mm (4.5
in) rectangular probe
cards up to 289 mm
(11.375 in) long
Simultaneous use of a
probe card and multiple
positioners/DC probe
needles
DC probe needles can be
used with the LP-PCH left
in place
Easy to use probe card clamp
Screw removal is not required to change similar types of probe
cards
No tools required to clamp the probe card in place
Back p ivoting edge connector for easy mating of edge ca rd
connector
Adjustable edge connector mounting brackets to support long
probe cards
Enables use of DCP probes without probe card in place
Quick switch-over between the TopHat cover and the LP-PCH
Maintains a dark and dry EMI-RFI shielded environment
(MicroChamber version o nly)
Accurate, front-located theta adjustment wheel
Stable 3-point planarization adjustment
Probe card height adjustment accommodates FormFactor low
leakage probe cards and ot her probe cards
Includes 48 pin and 70 pin ed ge connectors
Specifications
Maximum probe needle force: 1 kg (2.2 lb) (100 needles)
Temperature range:
System with MicroChamber -55°C to 2 00°C (-67° to F392°F)
With cover
Cover removed
PN 141-400 www.formfactor.com Probe Card Holders 102
Revision 57, February, 2023 Probe Station Accessories
System without Micr oChamber ambient t o 200°C (392°F)
Theta ran ge ±3°
Maximum planarization height compensation: 0.762 mm (0.030 in)
Probe card maximums:
W = 11.4 cm ±3 mm (4.5 in ±.012 in)
L = 15.25 cm 28.9 cm (6 in 11.375 in)
Thickness = 0.15 cm 0 .32 cm (0.060 in 0.125 in)
Compatibility
Summit
138-022 Clamp Kit for LLPC, in Low Profile Card
Holder
Features
Option to allow use of
shallow draft probe cards
For use on Low Profile
Probe Card Holder (120-
935) and Low-Profile Probe
Card Holder for Summit Stations with MicroChamber (124-118)
Specifications
Increases the draft from 2.03 to 4.57 mm (0.08 to 0.18 in)
Compatibility
Summit