141-400-57-probestationaccessoriescatalog.pdf_-_141-400-probestationaccessoriescatalog_1.pdf.pdf - 第122页

PN 141-400 www.formfactor.com Probe Mounts/Holders and Pro bes • 1 06 Revision 57, February, 2023 Probe Station A ccessories 100 64 9 — Pro b e Arm, R PP 305, Nor th-So uth Feat ur es • For u se with HF probes (e. g., |Z…

100%1 / 169
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 105
Revision 57, February, 2023 Probe Station Accessories
RF PROBE ARMS, RPP210-S
146041 Probe Arm, RPP210-S, North-South, for
Vacuum/Magnetic Platen
Features
For use with HF probes (e.g., |Z| Probe)
Positions the probe at the front or rear side of
DUT
Horizontal probe mounting platen can be
leveled
For use with vacuum and magnetic platen
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP210-S (and former PH110)
Arms are not compatible with EPS200RF, EPS20 0MMW, or PM8
with RF or MMW platen. For these systems, the platen adapter
(PN 1 00651) is required, or you may consult a FormFactor
representative for custom arms.
146042 Probe Arm, RPP210-S, East-West, for
Vacuum/Magnetic Plate
Features
For use with HF probes (e.g., |Z| Probe)
Positions the probe at the left or right side of
DUT
Horizontal probe mounting platen can be
leveled
For use with vacuum and magnetic platen
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP210-S (and former PH110)
Arms are not compatible with EPS200RF, EPS20 0MMW, or PM8
with RF or MMW platen. For these systems, the platen adapter
(PN 1 00651) is required, or you may consult a FormFactor
representative for custom arms.
RF PROBE ARMS, RPP305
100624 Probe Arm, RPP305, East-West, Mirrored
Features
For use with HF probes (e.g., |Z| Probe)
For positioning the probe on the left or right side
of DU T
Probe mounting platen ca n be leveled
Mirror image of 100648 (only for 2 port
configuration in combination with 100648)
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP305-S (and former PH25 0)
100647 Probe Arm, RPP305, East
Features
For use with HF probes (e.g., |Z| Probe)
For positioning the probe on the right side of
DUT
Probe mounting platen ca n be leveled (not
compatible with 4-port configuration)
Compatibility
All PA/PM stations (except MicroAlign) + RPP305-S (and former
PH250)
100648 Probe Arm, RPP305, East-West
Features
For use with HF probes (e.g., |Z| Probe)
For positioning the pr obe on the left or right side
of DU T
Probe mounting platen ca n be leveled
Mirror image of 100624 (for 4-port c onfiguration,
for 2-port configuration with 100624)
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP305-S (and former PH25 0)
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 106
Revision 57, February, 2023 Probe Station Accessories
100649 Probe Arm, RPP305, North-South
Features
For use with HF probes (e.g., |Z| Probe)
For positioning the probe at the front or rear
of DUT
Probe mounting platen can be leveled (for 4-
port configuration)
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP305-S (and former PH250)
118160 Probe Arm, RPP305, West
Features
For use with HF probes (e.g., |Z| Probe)
For positioning the probe on the left side of
DUT
Probe mounting platen can be leveled (not
compatible with 4-port configuration)
Compatibility
All PA/PM stations (except MicroAlign) + RPP305-S (and former
PH250)
169-672– RF Probe Arm Mounting
Platen
Features
Ena bles mounting of Lightwave probes
on RF arms
Compatibility
Probe stations: MPS150, PM8, PA200,
PM300 +
RF probe arms: RPP2xx (146041, 146042), RPP305 +
Lightwave probes: LWP-CLV-SM, LWP-CLV-MM, LWP-LEN-SM,
LWP-LEN-MM
RFA PROBE ARMS, RPP404/RPP404-W/RPP504
(COAX UP TO 67 GHZ)
RFA-67-EW
Features
East/West probe arm en ables mounting
of probe only (no frequency extender)
Compatible with 8-sided MicroChamber
TopHat or open (non-TopHat)
configurations
Compatibility
RPP404, RPP404-W, RPP504
positioners
RFA-67-EW-TH
Features
East/West probe arm en ables
mounting of probe only ( no
frequency extender)
Compatible with 8-sided
MicroChamber TopHat (includes
boot/FlexShield) or open (non-
TopHat) configurations
Compatibility
RPP404, RPP404-W, RPP504
positioners
Boot/FlexShield
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 107
Revision 57, February, 2023 Probe Station Accessories
RFA PROBE ARMS, RPP404/RPP404-W /RPP504
(COAX UP TO 130 GHZ WITH KEYSIGHT N5291A)
RFA-K120-EW
Features
East/West probe arm enables mounting of
Keysight N5291 frequency extender
Compatible with open (non-TopHat)
configurations
Compatibility
RPP404, RPP404-W, RPP504 positioners
RFA-K120-EW-TH
Features
East/West probe arm enables mounting of
Keysight N5291 frequency extender
Compatible with RF MicroChamber
TopHat (includes boot/FlexShield) or open
(non-To pHat) configurations
Compatibility
RPP404, RPP404-W, RPP504 positioners
RFA PROBE ARMS, RPP404/RPP404-W /RPP504
(MMWAVE AND THZ WITH VDI MINI EXTENDERS)
RFA-VDI-EW
Features
East/West probe arm enables
mounting of VDI Mini frequency
extender
Compatible with open (non-TopHat)
configurations
Compatibility
RPP404, RPP404-W, RPP504 positioners
RFA-VDI-EW-TH
Features
East/West arm enables mounting of
VDI Mini frequency extender
Compatible with RF MicroChamber
TopHat (includes boot/FlexShield) or
open (non-TopHat) configurations
Non-Tophat plates (for closer
coupling) and TopHat adapter included
Compatibility
RPP404, RPP404-W, RPP504 positioners
RFA PROBE ARMS, RPP404/RPP404-W/RPP504
(L
OAD-PULL WITH FOCUS MICROWAVES DELTA
TUNERS)
RFA-F67-E
Features
East probe arm enables mounting of
Focus Microwaves Delta Tuner
67 GHz, fundamental (C-672xx) /
harmonic (M-67100), load
Compatible with open (non-TopHat)
configurations
Compatibility
RPP404, RPP404-W, RPP504
positioners
RFA-F67-W
Features
West probe arm enables mounting of
Focus Microwaves Delta Tuner
67 GHz, fundamental (C-672xx) /
harmonic (M-67100), source
Compatible with open (non-TopHat)
configurations
Compatibility
RPP404, RPP404-W, RPP504 positioners
Boot/FlexShield