141-400-57-probestationaccessoriescatalog.pdf_-_141-400-probestationaccessoriescatalog_1.pdf.pdf - 第127页
PN 141-400 www.formfactor.com Probe Mounts/Holders and Pro bes • 1 11 Revision 57, February, 2023 Probe Station A ccessories DC P RO BE A RMS , M I CR O A L IGN 138 68 7 — P r ob e Arm, DPP 2x x/D PP 3x x, T r i ax Feat …

PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes • 110
Revision 57, February, 2023 Probe Station Accessories
RFA-MN5G-EW-TH
Features
• East/West arm enables
mounting of Maury
Nano5G frequency
extender
• Compatible with RF
MicroChamber TopHat
(includes boot/
FlexShield) o r open
(non-To pHat)
configurations
Compatibility
• RPP404, RPP404-W,
RPP504 positioners
RFA PROBE ARMS STORAGE POD
780-00169 — RFA Series Probe Arms Storage Pod
Features
• Ena bles safe storage of
populated RFA arms
• Stores RFA probe arms while
configured with probes, VNA
frequency extenders and/or
tuners, and as sociated port
savers and flex-shields.
• Ena bles safe and efficient RFA
arm changes and band
swapping
• Reduces the risk of damage to
the probe d uring arm changes
• Fitting hardware enables
placement of the VDI Mini
VNAX power supply to keep the
extender warm between band
swaps, minimizing drift and
maximizing prober utilization
• Integrated trays enable storage of probing accessories
• Ena bles probe assembly from a sitting position, away from the
prober
• A hinged, an ti-static, cleanroom-safe window prot ects probes from
accidental damage and prevents accidental probe tip contact,
while allowing safe, ergonomic probe arm loading
• Ergonomic hand grips ensure safe and secure handling of valuable
test equipment
• Each pod stores o ne populated probe arm
• Storage pod can be placed on the prober platen during band
swaps on the CM300 and Summit 12k / Summit 200 probe stations
(depending on configuration)
Specifications
• Dimensions (L x W x H): 350 x 175 x175 mm (or larger, depending
on stored parts [e.g., RFA-K220])
Compatibility
(* Denotes all variants)
• Compatible with, but not limited to, TopHat and non-TopHat
configurations with the following arms:
– RFA-67* - Coaxial sub 67 GHz pr obes
– RFA-K120* - Keysight Coaxial N5295AX03, used as part of
N5291A extenders up to 130 GHz
– RFA-K220* - N5291/VDI with T- Wave BB probe
– RFA-VDI* - VDI Waveguide Mini models and S geometry
Waveguide probes to 500 GHz, for both Tophat and non-Top Hat
– RFA-F* - Focus delta tuner arms
• Compatible with both FM4910 and UL94-V0 industry standards for
safety against combustion and smoke generation
TUNER INTEGRATION KITS
780-00612 — Integration Kit for Focus Microwave Tuner
M-4030 or L-4030 on CM300
Features
• Enables integration of
the Focus Microwave
Tuner M-4030 and L-
4030 on the CM300
• Positioner and tuner are
supplied by Focus
Microwave
Specifications
• eVue cover is required and included
Configuration
• Qty o ne required for each side
• Configurable with both East and West tuners
Compatibility
• CM300, Non-TopHat solution only
Arm, positioner, and probe
assembly shown
(transparent parts not included)

PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes • 111
Revision 57, February, 2023 Probe Station Accessories
DC PROBE ARMS, MICROALIGN
138687 — Probe Arm, DPP2xx/DPP3xx, Triax
Features
• For use with MicroAlign systems
• Highly isolated needle clamp for standard
single tips like PTT needles
• Stainless steel design for h igh rigidity and
minimum thermal drift
• Requires adaptation unit 138697 for use with
DPP3xx-S/DPP450-S
Specifications
• 0.75 m (2.5 ft) 50 Ohm low noise triax cable and 3 lug Triax plug
• DC leakage <10 fA at ambient temperature
• For use with temperature chucks up to 300°C (572°F)
Compatibility
• PA300 MicroAlign + DPP2xx, DPP3xx-S, DPP450-S (and former
PH110, PH150, PH400)
138690 — Probe Arm, DPP2xx/DPP3xx, Triax, Kelvin
1Tip
Features
• For use with MicroAlign systems
• For triaxial I/V-, Kelvin- and C/V (with CX-TRX
adapter) tests
• Stainless steel design for h igh rigidity and
minimum thermal drift
• Highly isolated needle clamp for single tips
like PTT needles (signal from force and sense already connected
inside chassis)
• Connector sockets for CommonRing cables (C/V-Test, 1 cable
included), guard potentials from force and sense are connected to
these sockets
• Requires adaptation unit 138697 for use with DPP3xx-S/DPP450-S
Specifications
• 2 x 0.75 m (2.5 ft) 50 Ohm low-noise triax cable and 3 lug Triax
plug
• For use with temperature chucks up to 300°C (572°F)
Compatibility
• PA300 MicroAlign + DPP2xx, DPP3xx-S, DPP450-S (and former
PH110, PH150, PH400)
138697 — Adapter for Probe Arms DPP2xx/DPP3xx to
Positio ner DPP3xx
Features
• Converts DPP3xx-S/DPP450-S front
plate for use with DPP2xx/DPP3xx
probe arms for DC and RF
applications on MicroAlign systems
Compatibility
• MPS150, EPS150, CM300xi stations, PM/PA stations + DPP3xx-S,
DPP450-S (and former PH15 0)
138700 — Probe Arm, DPP2xx/DPP3xx, Pico Probe
Features
• For MicroAlign systems
• Holding fixture for Active Pico probes from
GGB Pico probe 10…34 (Pico probe not
included)
• Stainless steel design for high rigidity and
minimum thermal drift
• Requires Test Equipment Interface 144987
for use at MicroAlign Adva nced systems
• Requires adaptation unit 138697 for use with DPP3xx-S/DPP450-S
Compatibility
• PA300 MicroAlign + DPP2xx, DPP3xx-S, DPP450-S (and former
PH110, PH150, PH400)
144866 — Probe Arm, DPP2xx/DPP3xx for DCP Probe
Features
• For MicroAlign systems
• For triaxial I/V-, Kelvin-, C/V (with CX-TRX
adapter) and 1/f applications
• Holding fixture for advanced DC coaxial
probes like AP&T Probes, DCP and
DCP-HTR probes
• Stainless steel design for high rigidity and minimum thermal drift
• Requires adaptation unit 138697 for use with DPP3xx-S/DPP450-S
• Includes (2) 0.7 m (2.3 ft) cables, 3-lug Triax-SSMC for IV an d
Kelvin measurements
Specifications
• DC leakage <10 fA at ambient temperature
Compatibility
• PA300 MicroAlign + DPP2xx, DPP3xx-S, DPP450-S (and former
PH110, PH150, PH400)

PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes • 112
Revision 57, February, 2023 Probe Station Accessories
RF PROBE ARMS, MICROALIGN
133302 — Probe Arm, RPP305, North-S outh
Features
• For MicroAlign systems
• 4 probe setup
• For adaptation of HF probes or probe
wedges
• For positioning the probe at front or rear
side of DUT
• Probe mounting plate can be levelled, adjustment drive screw
located at positioner end of the arm for easier op eration
• Requires HF add-on platen or RPP305-M
• For use with RPP305 positioners
Compatibility
• PM300PS, PA300 MicroAlign + RPP305 (and former PH25 0)
133303 — Probe Arm, RPP305, East-West
Features
• For MicroAlign systems
• 4 probe setup
• For adaptation of HF probes or
probe wedge s
• For positioning the probe at left or
right side of DUT
• Probe mounting plate can be
levelled, adjustment drive screw
located at positioner end of the arm for easier op eration
• Requires HF add-on platen or RPP305-M
• For use with RPP305 positioners
Compatibility
• PM300PS, PA300 MicroAlign + RPP305 (and former PH25 0)
134006 — Probe Arm, RPP305, East-West
Features
• For MicroAlign systems
• To accompany 133303 to place two
RPP305 (left and right) together in
front of the operator
• For adaptation of HF probes or probe
wedges
• For positioning the pr obe at left or right side of DUT
• Probe mounting plate can be levelled, adjustment drive screw
located at end of the arm for easier operation
• Requires HF add -on platen on probe platen or RPP305-M
• For use with RPP305 positioners
Compatibility
• PM300PS, PA300 MicroAlign + RPP305 (and former PH250)
144777 — Probe Arm, RPP210-S, East-West
Features
• For use with HF probes o r wedges
• Positions the probe at the left or right side
of DU T
• Horizontal probe mounting plate can be
levelled
• For use with HF platen and MicroAlign
• For use with RPP210-S (and former
PH110) positioners
Compatibility
• All PM/PA stations with RF platen, CM300 and PA300 MicroAlign,
RPP210-S (and former PH110)
144778 — Probe Arm, RPP210-S, North-South,
MicroAlign
Features
• For MicroAlign systems
• For use with HF probes o r wedges
• Positions the probe at th e front or rear side
of DU T
• Horizontal probe mounting plate can be
levelled
• For use with HF platen and MicroAlign
• For use with RPP210-S positioners
Compatibility
• All PM/PA stations with RF platen, CM300xi and PA300
MicroAlign, RPP210-S (and former PH110)