141-400-57-probestationaccessoriescatalog.pdf_-_141-400-probestationaccessoriescatalog_1.pdf.pdf - 第120页

PN 141-400 www.formfactor.com Probe Mounts/Holders and Pro bes • 1 04 Revision 57, February, 2023 Probe Station A ccessories 100 69 6 — P r ob e Arm, DPP 2x x/D PP 3x x, Ke lvin , 1 Tip Feat ur es • ( 2) 2 m (6.5 ft) coa…

100%1 / 169
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 103
Revision 57, February, 2023 Probe Station Accessories
Probe Mount s/Holders and Probes
Probe Arms and Probes (S-Positioner Compatible)
DC PROBE ARMS, DPP2XX/DPP3XX
100489 Ad apter Picoprobe 10-34A/DPP2xx/DPP3xx
Features
Holding fixture for active picoprobes
from GGB picoprobe 10…34
(picoprobe not included)
Integrates existing picoprobe with
DPP2XX or DPP3xx
Ada pter is included with FormFactor
standard picoprobes
Compatibility
MPS150, PM8, PM300, PA200, PA300
100524 Probe Arm, DPP2xx/DPP3xx, Edge Sensor
Features
Includes edge sensor tip
With connector matching to all semiautomatic
standard probe stations (check compatibility to
all other probe stations)
Compatibility
All PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
100525 Probe Arm, DPP2xx/DPP3xx, Triax
Features
1.5 m (5 ft) 5 0 Ohm low n oise triax cable and
triax plug BNC
Highly isolated and gold plated needle
clamping
Specifications
Max. operation temperature: 300°C (572°F)
Res istanc e*:
Leakage*:
Capacitance*:
* Spec test conditions for all cases: 25% humidity, shielded chamber, ambient
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
100560 Probe Arm, DPP3xx, Coax, BNC
Features
Short 50 Ohm coaxial cable and female BNC
connector mounted in DPP3xx positioner base
Requires additional coaxial cable (BNC male
connector)
Isolated a nd gold plated needle clamping
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP3xx-S, DPP450-S (and former PH150, PH400)
100561 Probe Arm, DPP2xx/DPP3xx, Coax, BNC
Features
2 m (6.5 ft) 50 Ohm coaxial cable with BNC
connector
Gold plated needle clamp
Specifications
Resistance: >100 TOhm
Leakage: < 120 fA
Capacitance: <300 pF
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
R_F-G @10V
T
100
R_G-S @10V
T
50
R_F-S @10V
T
300
F-G @10V@1min
fA
500
G-S @10V@1min
fA
2000
F-S @10V@1min
fA
500
C_F-G @300pA
pF
300
C_G-S @300pA
pF
500
C_F-S @300pA
pF
200
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 104
Revision 57, February, 2023 Probe Station Accessories
100696 Probe Arm, DPP2xx/DPP3xx, Kelvin, 1 Tip
Features
(2) 2 m (6.5 ft) coaxial cables, 50 Ohm and
BNC connector
Double arm design for improved stiffness,
with s ingle tip clamping (gold plated)
Shield connection can be changed
Connected for LCR measurements as
standard
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
100715 Probe Arm, DPP2xx/DPP3xx, Adjustable,
Coax, BNC
Features
2 m (6.5 ft) 50 Ohm coaxial cable and BNC
plug
Four hinges for individual arm profiling
Gold p lated needle clamping
Specifications
Res istanc e: >100TOhm
Leakage: <120fA
Capacitance: <300pF
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
131844 Probe Arm, DPP2xx/DPP3xx, Coax, High
Temperature
Features
For long term tests at temperatures higher
than 100°C and always with temperature
chucks up to 300°C
Specifications
1.5 m (6 ft) 5 0 Ohm c able with coaxial plug
BNC
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
133838 Front Plate for DC Arms
on RPP2xx Positioners
Features
Used for mounting DC Arms for ope n
systems on RPP2xx RF positioners
RF arm must be disassembled from the
RPP2xx positioner
Specifications
Used to moun t 1 (each) of 100489/100524/100525/100560/
100561/100696/100715/131844
Not for use with 144139
Compatibility
EPS150/200, PM8, PA200, PM300 + RPP2xx
144139 Probe Arm, DPP2xx/DPP3xx,
Flex, DCP Probes
Features
High rigidity
Stainless steel design for high rigidity and
minimum thermal drift
Requires adaptation unit 138697 for use with
DPP3xx/DPP450
DCP probes, cables and conn ectors not included base
Compatibility
MPS150, EPS150, all PA/PM open systems (exce pt MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH150,
PH400)
Note: DPP3xx-S and DPP450-S (and former PH15 0, PH400) require
138697 in order to mount this arm.
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 105
Revision 57, February, 2023 Probe Station Accessories
RF PROBE ARMS, RPP210-S
146041 Probe Arm, RPP210-S, North-South, for
Vacuum/Magnetic Platen
Features
For use with HF probes (e.g., |Z| Probe)
Positions the probe at the front or rear side of
DUT
Horizontal probe mounting platen can be
leveled
For use with vacuum and magnetic platen
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP210-S (and former PH110)
Arms are not compatible with EPS200RF, EPS20 0MMW, or PM8
with RF or MMW platen. For these systems, the platen adapter
(PN 1 00651) is required, or you may consult a FormFactor
representative for custom arms.
146042 Probe Arm, RPP210-S, East-West, for
Vacuum/Magnetic Plate
Features
For use with HF probes (e.g., |Z| Probe)
Positions the probe at the left or right side of
DUT
Horizontal probe mounting platen can be
leveled
For use with vacuum and magnetic platen
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP210-S (and former PH110)
Arms are not compatible with EPS200RF, EPS20 0MMW, or PM8
with RF or MMW platen. For these systems, the platen adapter
(PN 1 00651) is required, or you may consult a FormFactor
representative for custom arms.
RF PROBE ARMS, RPP305
100624 Probe Arm, RPP305, East-West, Mirrored
Features
For use with HF probes (e.g., |Z| Probe)
For positioning the probe on the left or right side
of DU T
Probe mounting platen ca n be leveled
Mirror image of 100648 (only for 2 port
configuration in combination with 100648)
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP305-S (and former PH25 0)
100647 Probe Arm, RPP305, East
Features
For use with HF probes (e.g., |Z| Probe)
For positioning the probe on the right side of
DUT
Probe mounting platen ca n be leveled (not
compatible with 4-port configuration)
Compatibility
All PA/PM stations (except MicroAlign) + RPP305-S (and former
PH250)
100648 Probe Arm, RPP305, East-West
Features
For use with HF probes (e.g., |Z| Probe)
For positioning the pr obe on the left or right side
of DU T
Probe mounting platen ca n be leveled
Mirror image of 100624 (for 4-port c onfiguration,
for 2-port configuration with 100624)
Compatibility
MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP305-S (and former PH25 0)