141-400-57-probestationaccessoriescatalog.pdf_-_141-400-probestationaccessoriescatalog_1.pdf.pdf - 第138页

PN 141-400 www.formfactor.com Probe Mounts/Holders and Pro bes • 1 22 Revision 57, February, 2023 Probe Station A ccessories Eli t e 300 and S um mi t DC Pr ob es 139 -3 31 — Coa xial Prob e (Str ai gh t ) Feat ur es • S…

100%1 / 169
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 121
Revision 57, February, 2023 Probe Station Accessories
151-290 PTT Needle Probe Mount, 40 mm, HTS,
Enhanced Jack Lock Holder, MS1 Series
Features
Enh anced probe mount for PTT needle
probes (45°)
For use on Elite 300
Compatible with MicroChamber TopHat
Easy probe needle replacement
without tools
Compatible with all 45
o
PTT series
probe needles
Compatible with MS1 programmable positioners
Kit Contents
Probe to positioner mount
Jack lock holder with SSMC (f) a nd pin jack (f) connectors
1 m (3.3 ft) coax (m) to SSMC (m)
46 cm (18 in) cable with pin jack (m) to (m)
EMI grounding strap
Compatibility
Elite 300/AP, Elite 300/M, Summit (with HTS platen upgrade)
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 122
Revision 57, February, 2023 Probe Station Accessories
Elite 300 and Summit DC Probes
139-331 Coaxial Probe (Straight)
Features
Shielded DC measurements with
coaxial probe
Straight configuration for multiple
probing applications when using straight o r 4 n eedles for steep
access
Easy probe needle replacement
without tools
Compatible with all PTT series
probe needles
Replaceable SMA cable
Easy connection to Elite 300
coax connection panel on
platen
The temperature of the cable
containing arm mus t not e xceed
200°C. Usually this is suitable
for 300°C wafer temperature in
an op en setup with an a rm at
least 10mm above the wafer.
Kit Contents
Straight shielded probe
Integrated SMA (f) connector
Shielded coaxial cable, 76 cm (30 in) with SMA (m) to BNC plug
Compatibility
Elite 300, Summit, SUMMIT200
139-870 Coaxial Probe (Bent)
Features
Shielded DC measurements with
coaxial probe
Ben t configuration for increased
microscope objective clearance with
high magnification/low working distance objective lenses
Easy probe needle replacement without tools
Compatible with all bent PTT series probe needles
Replaceable SMA cable
Easy connection to Elite 300
coax connection panel on
platen
The temperature of the cable
containing arm must not
exceed 200°C. Usually this is
suitable for 300°C wafer
temperature in an open setup
with an arm at least 10mm
above the wafer.
Kit Contents
Bent 35° shielded probe
Integrated SMA (f) c onnector
Shielded coaxial cable, 76 cm (30 in) with SMA (m) to BNC plug
Compatibility
Elite 300, Summit, SUMMIT200
144-390 Triaxial Probe (Straight)
Features
Guarded DC measurements with
triaxial probe
Integrated triaxial cable for low-
noise measurements
Easy connection to Elite 300
triaxial connection panel o n
platen
Straight configuration for multiple probing applications when using
straight or 45° needles f or steep access
Easy p robe needle replacement without tools
Compatible with all PTT series probe needles
The temperature of the cable containing arm must not exceed
200°C. Usually this is suitable for 300°C wafer temperature in an
open setup with an arm at least 10mm above the wafer.
Kit Contents
Straight triax probe
Integrated triaxial low-noise cable, 76 cm (30 in) with triax (m)
connector
Compatibility
Elite 300, Summit, SUMMIT200
Two (2) DPP2xx positioners
and u niversal probe mounts,
one u sing the straight coax
probe with straight needle, and
the other using a be nt coax
probe with 45° bent PTT needle
Coaxial pr obe (bent) with 45°
PTT ne edle, shown attached to
universal pr obe holder and
DPP2xx positioner.
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 123
Revision 57, February, 2023 Probe Station Accessories
144-391 Triaxial Probe (Bent)
Features
Guarded DC mea sure ments with
triaxial probe
Integrated triaxial cable for low-noise measurements
Easy connection to Elite 300 triaxial connection panel on p laten
Ben t configuration for increased microscope objective clearance
with high magnification/low working distance objective lenses
Easy probe needle replacement without tools
Compatible with all 45° PTT serie s probe needles
The temperature of the cable containing arm must not exceed
200°C. Usually this is suitable for 300°C wafer temperature in an
open setup with an arm at least 10mm above the wafer.
Kit Contents
Ben t 35 ° triax probe
Integrated triaxial low-noise cable, 76 cm (30 in) with triax (m)
connector
Compatibility
Elite 300, Summit, SUMMIT200
144-392 Unshielded Probe Kit
Features
Interchangeable probe arms
(unshielded)
Easy probe needle
replacement without tools
Pin jack for DC electrical connection
Compatible with all PTT series probe needles
Kit Contents
Collet adapter with pin lock
connector (f)
Straight u nshielded probe arm
with jack lock
35° bent unshielded probe arm
with jack lock
46 cm (18 in) cable with pin jack
(m) to (m)
Compatibility
Elite 300, Summit, SUMMIT200
PHQ Quick Lock Probe Holder
Features
Replacement probe ti p
holder for MMP probes
Quick lock needle holding
mechanism (spring-loaded
Collette style)
Constructed of nickel plated brass that can be user-formed as
needed
Specifications
114 mm (4.5 in) in length
Nickel plated brass
Quick lock mechanism
Kit Contents
Probe tip holder
MAE-44/18 cable 46 cm (18 in)
Compatibility
Summit
PHW Wrench Lock Probe Holder
Features
Replacement probe ti p
holder for MMP probes
Wrench lock needle holding
mechanism (set screw hold)
Constructed of nickel plated
brass that can be user-formed as needed
Specifications
114 mm (4.5 in) in length
Nickel plated brass
Wrench lock mechanism
Kit Contents
Probe tip holder
MAE-44/18 cable 46 cm (18 in)
Allen wrench
Compatibility
Summit
Unshielded probe (straight)
and collet shown attached to
universal probe holder and
DPP2xx positioner