4.1.2 Main Air Pressure Check
Cycle : Every Day (Required Time : 1 minute)
Main Air Pressure
F4A9
Procedure
Set Air Pressure 0.45 MPa (4.6 kgf/cm
2
) Check to see that the air pressure is "Min.
0.4 MPa (4.1 kgf/cm
2
)" while the machine is running.
If not, adjust the air pressure.
4.1 Air Source
4OM-1751
1-201304-001
4.1.3 Drain Check
Cycle : Every Week (Required Time : 5 minutes)
Cap
Drain
F4A10
Procedure
 
section to drain.
4.1 Air Source
4OM-1751
1-211304-001
4.1.4 Filter Cleaning
Cycle : Every 3 Months (Required Time : 5 minutes)
Filter
F4A11
Procedure
  
case removing jig to remove the cover.
F4A12
4.1 Air Source