4OM-1751 1-33 4.7 Head Section High-Speed Head Linear Measure Sensors (Light Emitter and Receiver) Every Day Cleaning Required T ime: 5 minutes When any fat or oil is stuck to the line sensor , rub off the dirt using a c…

4OM-1751
1-321304-001
4.6.2 Cutter Unit Inside Oiling
Cycle : Every 3 Months (Required Time : 10 minutes)
Cutter Unit
F4A24
Procedure
(1) Remove the front cover.
(2) Clean the debris and dust in the cutter unit using a vacuum cleaner.
Note
Use a vacuum cleaner with a narrow air opening in the nozzle.
Narrow Air Opening in Nozzle End
(Recommended)
F4A25
CAUTION
After making sure that the air supply has been stopped and the
cutter blades are closed, start maintenance.
During maintenance, do not touch the cutter blade.
4.6 Cutter Section

4OM-1751
1-33
4.7 Head Section
High-Speed Head
Linear Measure Sensors
(Light Emitter and Receiver)
Every Day Cleaning
Required Time: 5 minutes
When any fat or oil is stuck to the line sensor,
rub off the dirt using a cotton applicator dipped
in dehydrated ethanol.
Nozzle U/D Ball Screw (NL Axis)
Every 3 Months Cleaning and Lubrication
(DAPHNE GREASE MP No. 1)
Required Time: 5 minutes
Use No. 19 (brown) nozzle.
Note
No. 19
Wipe off the old grease with a rag and apply a
small amount of new grease to the groove of
the ball screw with a syringe.
Notice
Diffusion Plate
Every Month Cleaning
Required Time: 2 minutes
(1) Store all nozzles in the nozzle stocker
(housing) through window navigations.
(2)
Sebum or oil should not
adhere to the surface of the
diffusion plate.
Refer to "5. Nozzle Change
Window" in "Chapter 6 (Vol. 2)"
for the procedure of nozzle storage.
Reference
Wipe the diffusion plate with a dry lens
cleaning cloth.
F4A26
1304-001
4.7 Head Section

4OM-1751
1-34
Notice
Head U/D Ball Screw (HL Axis)
(1) Wipe off the old grease with a rag and
apply a small amount of new grease to the
groove of the ball screw with a syringe
(2) After lubrication, move the HL-axis up
and down 25 mm five times using the
manual axis operation to smooth the grease.
No.19
(3) Grease should be applied every 3 months
after the initial month.
Apply grease, taking care that
the grease does not stick to the
sensor.
No.19
Every 3 Months Cleaning and Lubrication
(DAPHNE GREASE MP No. 1)
Required Time: 5 minutes
Use No. 19 (brown) nozzle.
Note
Head U/D Linear Guide (HL Axis)
Every 3 Months Cleaning and Lubrication
(DAPHNE GREASE MP No. 1)
Required Time: 5 minutes
(1) Wipe off the old grease with a rag and
apply a small amount of new grease to the
groove of the ball screw with a syringe
(2) After lubrication, move the HL-axis up
and down 25 mm five times using the
manual axis operation to smooth the grease.
Use No. 19 (brown) nozzle.
Note
F4A27
1304-001
4.7 Head Section