4 Operation
4.15 Testing new flux types
54 User Manual SIPLACE Linear Dipping Unit E 12/2018
Performing the measurement
Measurement 1
► Hold the measuring device with your thumb and forefinger on its handle.
► (1) Place the measuring device with the point which is opposite the zero value of the scale
onto the flux surface and press down to the base of the cavity.
► (2) Apply slight pressure and roll the measuring device in one direction to the zero value (3).
► Take the measuring device vertically up and out of the flux.
► Determine on the middle roller the point (2) where the flux starts to coat the middle roller.
► Read the value on the scale at this point.
Measurement 2
► Repeat the measurement by rolling the measuring device in the opposite direction as far as
the zero value.
► Read the value shown on the scale.
► Calculate the mean value of both measuring results.
4.15 Testing new flux types
If you use a new flux, then proceed as follows during the test phase:
► Calculate the relevant cavity for the product.
► Place the corresponding dip plate in the LDU.
► Fill in the flux.
► Set the application speed as slow.
► Increase the application speed in steps.
► While doing this, observe the flux surface.
► Reduce the application speed again, if waves, dips or irregularities are formed on the surface.
► Select a long dwell time. This can be reduced later to achieve higher cycle times.
► Select a slow start for the upwards movement of the placement head after dipping. This en-
sures that the component is not lost in the flux.

4 Operation
4.16 Performing a self-test
User Manual SIPLACE Linear Dipping Unit E 12/2018 55
4.16 Performing a self-test
► In the station software, select the Single
functions view(1) and then the Subsys-
tems area (2).
► Select the Location (3) on which the LDU
is set up.
► Select the Feeder area (1).
► Select the LDU in the list of set up feeders
(2).
► Click on the Details…button (3).
► Click on the Self-test button.
The LDU performs a self-test.

4 Operation
4.17 Operating the control unit
56 User Manual SIPLACE Linear Dipping Unit E 12/2018
4.17 Operating the control unit
Logging off
► Use the Up (1) or Down key (2) to select the operating mode P0.
► Press the Select key (3).
The LDU will be logged off and unlocked from the placement machine.
► Remove the LDU from the changeover table.
Starting a reference run
► Use the Up (1) or Down key (2) to select the operating mode P1.
► Press the Select key (3).
The LDU performs a reference run.
Refreshing the dipping medium
► Select with the Up (1) or Down key (2) the operating mode P2.
► Press the Select key (3).
The LDU performs a squeegee movement.