4OM-1075-002.pdf - 第180页

Error ID Item Description 140551 Elevator #2 Axis Servo Alarm Overspeed. 140571 Elevator #2 Axis Servo Alarm Overload: High load. 140572 Elevator #2 Axis Servo Alarm Overload: Low load. 140573 Elevator #2 Axis Servo Alar…

100%1 / 299
Error ID Item Description
140301 Elevator #2 Axis Data The driver data was detected outside of the possible
range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
140401 Elevator #2 Axis Limit (+) Limit error has been detected.
140402 Elevator #2 Axis Limit (-) Limit error has been detected.
(Cause 1) The X1 axis might have overrun due to generation of noises, overcurrent, etc.
The sensor may be defective.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
140502 Elevator #2 Axis Servo Alarm Parameter breakdown.
140503 Elevator #2 Axis Servo Alarm Main circuit encoder error.
140504 Elevator #2 Axis Servo Alarm Parameter setting error.
140505 Elevator #2 Axis Servo Alarm Combination error.
140510 Elevator #2 Axis Servo Alarm Overcurrent or heat sink overheated.
140530 Elevator #2 Axis Servo Alarm Regenaration error detected.
140532 Elevator #2 Axis Servo Alarm Regenarative overload.
140540 Elevator #2 Axis Servo Alarm Overvoltage.
140541 Elevator #2 Axis Servo Alarm Undervoltage.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-87 AHB01ETRP
Error ID Item Description
140551 Elevator #2 Axis Servo Alarm Overspeed.
140571 Elevator #2 Axis Servo Alarm Overload: High load.
140572 Elevator #2 Axis Servo Alarm Overload: Low load.
140573 Elevator #2 Axis Servo Alarm Dynamic brake overload.
140574 Elevator #2 Axis Servo Alarm Overload of surge current limit resistor.
14057a Elevator #2 Axis Servo Alarm Heat sink overheated.
140581 Elevator #2 Axis Servo Alarm Encoder backup error.
140582 Elevator #2 Axis Servo Alarm Encoder checksum error.
140583 Elevator #2 Axis Servo Alarm Absolute encoder battery error.
140584 Elevator #2 Axis Servo Alarm Encoder data error.
140585 Elevator #2 Axis Servo Alarm Encoder overspeed.
140586 Elevator #2 Axis Servo Alarm Encoder overheated.
140591 Elevator #2 Axis Servo Alarm Overload warning.
140592 Elevator #2 Axis Servo Alarm Regenerative overload warning.
140594 Elevator #2 Axis Servo Alarm Setting warning.
140595 Elevator #2 Axis Servo Alarm Command warning.
140596 Elevator #2 Axis Servo Alarm Communications warning.
1405b1 Elevator #2 Axis Servo Alarm Reference speed input read error.
1405b2 Elevator #2 Axis Servo Alarm Reference torque input read error.
1405b6 Elevator #2 Axis Servo Alarm Gate array error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-003 2-88 AHB01ETRP
Error ID Item Description
1405bf Elevator #2 Axis Servo Alarm System alarm.
1405c1 Elevator #2 Axis Servo Alarm Servo overrun detected.
1405c6 Elevator #2 Axis Servo Alarm Fully closed loop phase A/B disconnected.
1405c7 Elevator #2 Axis Servo Alarm Fully closed loop phase C disconnected.
1405c8 Elevator #2 Axis Servo Alarm Absolute encoder clear error and multiturn limit
setting error.
1405c9 Elevator #2 Axis Servo Alarm Encoder communications error.
1405ca Elevator #2 Axis Servo Alarm Encoder parameter error.
1405cb Elevator #2 Axis Servo Alarm Encoder echoback error.
1405cc Elevator #2 Axis Servo Alarm Multiturn limit disagreement.
1405d0 Elevator #2 Axis Servo Alarm Position error pulse overflow.
1405e0 Elevator #2 Axis Servo Alarm No option unit installed.
1405e1 Elevator #2 Axis Servo Alarm No response from the board in the option unit.
1405e2 Elevator #2 Axis Servo Alarm Option WDC error.
1405e5 Elevator #2 Axis Servo Alarm WDT error.
1405e6 Elevator #2 Axis Servo Alarm Communications error.
1405ea Elevator #2 Axis Servo Alarm SERVOPACK damaged.
1405eb Elevator #2 Axis Servo Alarm SERVOPACK initial access error.
1405ec Elevator #2 Axis Servo Alarm SERVOPACK WDC error.
1405ed Elevator #2 Axis Servo Alarm Command execution incomplete.
1405f1 Elevator #2 Axis Servo Alarm Power line open phase.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-89 AHB01ETRP