4OM-1075-002.pdf - 第295页

Error ID Item Description 10 57 0 00000 ---- Result was out of tolerance. 10 57 0 00001 ---- Nozzle outward was out of tolerance. 10 57 0 00002 ---- The teaching operation did not end within the speci- fied number of tim…

100%1 / 299
4.3.5 Various Teaching Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (0 and 6)
Primary Error Classification (0 to 99)
Classification of Recognition Functions (10)
(a) Error IDs "*" will be filled with detail codes.
(b) When an error ID other than the described ones is issued,
contact our service personnel for some advice.
Table 4B14
Error ID Item Description
10 00 0 00000 ---- Others
10 54 0 00000 ---- There is a big difference X and Y in the result of
magnification.
10 54 0 00001 ---- The measured magnification does not meet the
specifications of the machine.
10 54 6 76030 ---- Contrast between dot and background is too low.
10 54 6 76031 The dots cannot be detected adequately.
(Cause 1) An error occurred during the teaching operation of the camera magnification
and the angle.
(Remedy 1) Contact our service personnel for details.
10 55 0 00000 ---- The teaching operation did not end within the
specified number of time.
10 55 0 00001 ---- Back lighting OFF
10 55 0 00002 ---- Gain or Level exceed the range of tuning.
(Cause 1) An error occurred during the teaching operation of the camera gain and level.
(Remedy 1) Contact our service personnel for details.
4.3 Recognition Error IDs and Remedial Procedures
0308-004 2-150 AHB01ETRP
Error ID Item Description
10 57 0 00000 ---- Result was out of tolerance.
10 57 0 00001 ---- Nozzle outward was out of tolerance.
10 57 0 00002 ---- The teaching operation did not end within the speci-
fied number of time.
10 57 0 00003 ---- Brightness exceeds the range of tuning.
10 57 0 010** ---- The lamp (right side) for the P.E.C. recognition did
not illuminate.
10 57 0 011** ---- The lamp (left side) for P.E.C. recognition did not
illuminate.
10 57 0 0120* ---- The lamp for back lighting in the movable lighting
system (right side) did not illuminate.
10 57 0 0121* ---- The upper lamp for front lighting in the movable light-
ing system (right side) did not illuminate.
10 57 0 0122* ---- The middle lamp for front lighting in the movable
lighting system (right side) did not illuminate.
10 57 0 0123* ---- The lower lamp for front lighting in the movable light-
ing system (right side) did not illuminate.
10 57 0 0130* ---- The lamp for back lighting in the movable lighting
system (left side) did not illuminate.
10 57 0 0131* ---- The upper lamp for front lighting in the movable light-
ing system (left side) did not illuminate.
10 57 0 0132* ---- The middle lamp for front lighting in the movable
lighting system (left side) did not illuminate.
10 57 0 0133* ---- The lower lamp for front lighting in the movable light-
ing system (left side) did not illuminate.
10 57 0 0140* ---- The lamp for back lighting in the fixed lighting sys-
tem (Side A) did not illuminate.
10 57 0 0141* ---- The upper lamp for front lighting in the fixed light-
ing system (Side A) did not illuminate.
10 57 0 0142* ---- The middle lamp for front lighting in the fixed light-
ing system (Side A) did not illuminate.
10 57 0 0143* ---- The lower lamp for front lighting in the fixed lighting
system (Side A) did not illuminate.
(Cause 1) An error occurred during the teaching operation of the lighting.
(Remedy 1) Contact our service personnel for details.
0206-002 2-151 AHB01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Error ID Item Description
10 57 0 0150* ---- The lamp for back lighting in the fixed lighting sys-
tem (Side B) did not illuminate.
10 57 0 0151* ---- The upper lamp for front lighting in the fixed light-
ing system (Side B) did not illuminate.
10 57 0 0152* ---- The middle lamp for front lighting in the fixed light-
ing system (Side B) did not illuminate.
10 57 0 0153* ---- The lower lamp for front lighting in the fixed lighting
system (Side B) did not illuminate.
10 57 0 016** ---- The lamp for back light stage did not illuminate.
(Cause 1) An error occurred during the teaching operation of the lighting.
(Remedy 1) Contact our service personnel for details.
4.3 Recognition Error IDs and Remedial Procedures
0206-001 2-152 AHB01ETRP