Nordson_EFD_P-Jet_SolderPlus_Operating_Manual.pdf - 第23页
Liquidyn P-Jet SolderPlus Jet Valve 23 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. Connect the Air Supply To achieve consistent disp…

Liquidyn P-Jet SolderPlus Jet Valve
22 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Connect Cables
Connect the M8 valve cable and other communication cables as applicable for your system to control the operation
of the valve. The diagram below shows some typical system control setups.
NOTE: The valve is triggered by a square-wave signal (24 VDC). The length of the pulse from the control signal
defines the opening time of the valve and can be set from 2 ms to infinity. Most PLC systems make use of high
performance transistor outputs which are suitable to control the valve directly. The valve is electrically connected to
the control system via the supplied M8 valve cable.
V10
V200
PLC
PLC
PLC
P-Jet SolderPlus
V10
V200
V10
T10
PLC
P-Jet SolderPlus
P-Jet SolderPlus
P-Jet SolderPlus
P-Jet SolderPlus
P-Jet SolderPlus
Key:
T10 = Liquidyn T10 or T20 heater controller
V10 = Liquidyn V10, V10M, V10D, or M10D controller
V200 = Liquidyn V200 controller
PLC = Higher-level controller

Liquidyn P-Jet SolderPlus Jet Valve
23www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Connect the Air Supply
To achieve consistent dispensing results, the process parameters must be kept constant. The valve has two air
pressure connections (operating pressure and fluid pressure) which must be continuously supplied with air pressure.
The level of pressure depends on the respective process. Each valve must be separately connected to a continuous
air supply adjustable through a precision pressure regulator. To keep the operating pressure stable and constant,
use a pneumatic accumulator (at least 0.4 liter volume).
For an air supply connection diagram, refer to “Installation Example” on page24.
CAUTION
Ensure that the pressure limit values for the syringe barrel and air pressure tubing are not exceeded.
1. For the operating pressure, connect 6 mm OD tubing to the plug-in connector on the side of the valve.
2. For the fluid pressure, connect 4 mm or 6 mm tubing to the syringe barrel adapter.
NOTE: Nordson EFD recommends installing a precision pressure regulator with a maximum control tolerance of
0.2%.
Air input (operating
pressure)
Air input
(fluid pressure)

Liquidyn P-Jet SolderPlus Jet Valve
24 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Installation Example
Item Description
Pneumatic connections
• Compressed air tube, 6 mm OD
• Dry, filtered air pressure, oil-free
• Filter grade: 40 µm
• Regulated by a precision pressure regulator
• Operating pressure limit: 3–8 bar (44–116 psi)
Fluid connection
• Syringe barrel accessories with compressed 4 mm air tubing
• Fluid pressure limit: 100 bar (1450 psi)
Electrical connections
• Supplied M8 valve cable from the valve to a Liquidyn valve controller or a higher-
level controller, such as a PLC
• Power supply: 24 VDC
• Power consumption: 0.5 Amp (peak 5.0 Amp)
Optional
• Nozzle heater (controlled by a temperature control unit)
• Process equipment (such as a laser light barrier for dot recognition or a cleaning
station for nozzles)
Liquidyn P-Jet SolderPlus valve connection diagram
Syringe barrel connection
Higher-level controller
(e.g., PLC)
Valve cable
4 mm air supply tubing
Fluid pressure
Precision
pressure
regulator
Precision
pressure
regulator
Air pressure source
Pressure
accumulator
(at least 0.4 liter)
Operating pressure
6 mm air supply tubing
P-Jet
SolderPlus
Temperature
controller (e.g.,
V200, T10)
Nozzle heater
cable