Nordson_EFD_P-Jet_SolderPlus_Operating_Manual.pdf - 第48页

Liquidyn P-Jet SolderPlus Jet Valve 48 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. T o Change the Nozzle 1. Shut off the air supply …

100%1 / 50
Liquidyn P-Jet SolderPlus Jet Valve
47www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Appendix C, Special Instructions for Solder Paste
Dispensing
This appendix provides startup, operating, and service instructions that are unique to solder paste dispensing using
the P-Jet SolderPlus valve. These instructions are cross-referenced at the applicable locations within this manual.
To Bring Solder Paste into the Nozzle at Initial Startup
Before the initial dispensing of solder paste, material must be introduced into the nozzle.
1. Begin with the following system settings:
Pulse Time 1 s (equivalent to 1000 ms + frequency >1Hz)
Fluid pressure (P1) 2 bar (30 psi)
Operating pressure (P2) 6 bar (87 psi)
Tappet force screw 55 N (33–35 clicks)
Tappet stroke 270°
Nozzle heater temperature 38–40° C (100–104° F)
2. Initiate a signal to the valve.
3. When solder paste flows out of the nozzle, stop the signal to the valve.
To Adjust the Tappet in a Solder Paste Dispensing Application
CAUTION
Do not adjust the tappet of a wetted and closed valve. Doing so can grind material into the nozzle, causing nozzle
clogging and other problems.
To properly adjust the tappet of a valve used in a solder paste dispensing application, supply a constant signal to
the valve to lift the tappet, then adjust the force screw or stroke. Refer to “Tappet Adjustment” on page28 for
detailed procedures.
Settings for Constant Dispensing of Solder Paste (Routine Operation)
Use the following settings for the constant dispensing of solder paste during routine operation of the solder paste
system:
Pulse Time 6 ms
Frequency 25Hz
Fluid pressure (P1) 2 bar (30 psi)
Operating pressure (P2) 6 bar (87 psi)
Tappet force screw 55 N (33–35 clicks)
Tappet stroke 270°
Nozzle heater temperature 38–40° C (100–104° F)
Liquidyn P-Jet SolderPlus Jet Valve
48 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
To Change the Nozzle
1. Shut off the air supply to the valve (P1).
2. Important: Supply a constant signal to the valve to lift the tappet (Pulse Time = 1 s).
3. Close the valve by stopping the signal to the valve.
4. Remove the nozzle heater retaining nut and then remove the nozzle heater and nozzle.
5. Clean the tappet and the space between tappet and the fluid body.
6. Install the replacement nozzle, the nozzle heater, and the nozzle retaining nut.
7. Close the valve by stopping the signal to the valve.
CAUTION
Do not adjust the tappet of a wetted and closed valve. Doing so can grind material into the nozzle, causing nozzle
clogging and other problems.
8. Return the tappet force screw (stroke) to the correct setting.
NOTE: There must be no material between the tappet and the nozzle.
Appendix C, Special Instructions for Solder Paste
Dispensing (continued)
To Service All Wetted Parts (Valve Cleaning)
1. Disassemble the valve as shown in the disassembly procedures contained in this manual. No special
disassembly steps are required.
2. Assemble the valve as shown in the assembly procedures contained in this manual up to step 4 on page 34
(installing the nozzle).
3. Before installing the nozzle, supply a constant signal to the valve to lift the tappet (Pulse Time = 1 s).
4. Install the nozzle, the nozzle heater, and the nozzle retaining nut.
5. Close the valve by stopping the signal to the valve.
CAUTION
Do not adjust the tappet of a wetted and closed valve. Doing so can grind material into the nozzle, causing nozzle
clogging and other problems.
6. Return the tappet force screw (stroke) to the correct setting.
NOTE: There must be no material between the tappet and the nozzle.
7. Continue with step 7 on page 34.
Liquidyn P-Jet SolderPlus Jet Valve
49www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Notes