2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS -50 SIPLACE HS -50 2.6 Activating t he Option 01/01 Issue 100 Å If yo u would l ike the mec hanical cerami c substr ate ce ntering un it in combi nat…

100%1 / 124
SIPLACE HS-50 2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS-50
01/01 Issue 2.6 Activating the Option
99
Å The following options are available in the "Edit" window.
CAUTION
The options "Oblique illumination" or "None" are not relevant for the ceramic substrate centering
unit.
If you select one of these options, the mechanical ceramic substrate centering unit must be com-
pletely DEinstalled first and the corresponding conveyor must be reinstalled for PCB clamping as
described in the Service Manual.
If this is overlooked, this may result in damaged to the next PCB or to the mechanical ceramic
substrate centering unit.
Å If you wish to have the mechanical ceramic substrate centering unit in combination with the
substrate position recognition via PCB camera (normal illumination) or optional multicolor PCB
camera, choose:
0HFKDQLFDO VXEVW UDWHFHQWHULQJ-> "Accept".
2SWLRQLQWKH(GLWPHQX ([SODQDWLRQ
NONE Normal PCB conveyor with PCB clamp and PCB position
recognition via PCB camera with normal illumination or
optional multicolor PCB camera.
The mech. ceramic substrate centering unit MUST be dein-
stalled and the conveyor must be equipped to keep PCBs
in place.
0HFKDQLFDOVXEVWUDWHFHQWHULQJ
Mechanical ceramic substrate centering unit AND
substrate position recognition by means of PCB camera
(normal illumination) or multicolor PCB camera.
Oblique illumination No mechanical centering,
ONLY position recognition for PCBs via optional oblique
illumination (annular lamp)
-> Oblique illumination is always possible for both convey-
ors only.
ATENTION:
For this purpose the mech. ceramic substrate centering unit
MUST be deinstalled and the conveyor must be equipped
to clamp PCBs.
0HFKDQLFDODQGRE OLTXHLOOXPL
QDWLRQ
Mechanical ceramic substrate centering unit AND substrate
position recognition via optional oblique illumination of the
PCB camera.
-> Oblique illumination is always possible for both convey-
ors only.
2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS-50 SIPLACE HS-50
2.6 Activating the Option 01/01 Issue
100
Å If you would like the mechanical ceramic substrate centering unit in combination with substrate
position recognition, select:
0HFKDQLFDODQGREOLTXHLOOXPLQDWLRQ
-> "Accept".
Å If the machine has only a single conveyor, exit the menu "Machine configuration" now by se-
lecting "Accept".
In the following cases a NOTE or error message is output on the screen:
A NOTE will be output,
if you selected toe SITEST menu option "None" or "Oblique illumination", i.e., a menu option
WITHOUT the mechanical ceramic substrate centering unit, although the mech. ceramic
substrate centering unit is still INSTALLED as hardware.
-> The note text indicates that, before continuing, the mechanical ceramic substrate center-
ing unit in the pertinent conveyor must be deinstalled and the plug-in connections on the
conversion board of the conveyor control must be unplugged.
Otherwise the PCB and/or the mechanical ceramic substrate centering unit (X-centering
unit) may be damaged.
An ERROR message is output,
if you have selected the SITEST menu option "Mechanical" or "Mechanical and oblique il-
lumination", i.e., a menu option WITH mechanical ceramic substrate centering although NO
ceramic substrate centering unit hardware has been installed or it has not been installed
completely.
-> The message indicates that the option is not installed in the appropriate conveyor or, in
connection with a completed retrofitting of the option for example, the corresponding plug-
in connection on the conveyor control is missing, is poor or has been incorrectly allocated.
Å If a dual conveyor is installed, you then select in the menu "Edit":
"Ceramic substrate centering conveyor
".
Configure the mechanical substrate centering unit as described above for conveyor 1.
Note the following, however, insofar as possible combinations between conveyor 1 and 2 are
concerned:
The combination "None" and "Mechanical substrate centering" is possible if the pertinent
conveyor is appropriately equipped (with or without mechanical ceramic substrate center-
ing unit).
The combination of a position recognition with oblique illumination in one conveyor and with
normal illumination or "None" in another is NOT possible. If this constellation is selected,
position recognition with oblique illumination is automatically accepted for BOTH convey-
ors.
Therefore, in this case the mechanical ceramic substrate centering unit must always be
DEINSTALLED in both conveyors and the plug-in connections have to be unplugged from
the the conversion boards of the conveyor control.
SIPLACE HS-50 2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS-50
01/01 Issue 2.6 Activating the Option
101
Otherwise, this may result in damage to the PCB and or the mechanical ceramic substrate
centering unit (X-centering unit).
Å Select "Accept" to exit the "Machine configuration" menu.
If the selected menu option differs from the hardware situation "mechanical ceramic substrate
centering unit present/not present", when you exit this menu an error message or note will be
output, as described above during the configuration of conveyor 1.
Å Exit the SITEST program.
Å Carry out the shut-down the machine and execute a machine restart so that the configuration
will be accepted.
Å Check the function of the mechanical ceramic substrate centering unit (see Section 2.7).