 5HW UR ILW.LW
NOTE:
The retrofit kit contains only the components for ONE processing area.
Therefore 2 retrofit kits are required for each PCB conveyor.
5HWURILWNLW0HFKDQLFDOFHUDPLFVXEVWUDWHFHQWHULQJXQLW+6
,WHPQR FRQVLVWLQJRI
Ceramic substrate centering unit HS-50 (X-slide unit)
incl. proximity switch and compressed
air connection, completely assembled Item no. 00347287-01
Stop rail 1, assembly
WITH PARALLEL PIN for 50 mm to 62 mm Item no. 00358877-01
Stop rail 2, assembly for > 62 mm to 106 mm Item no. 00358884-01
Stop rail 3, assembly for > 106 mm to 140 mm Item no. 00358885-01
Stop unit, kit 1 for 50 mm to 62 mm Item no. 00357326-01
Stop unit, kit 2 for > 62 mm to 106 mm Item no. 00357324-01
Stop unit, kit 3 for > 106 mm to 140 mm Item no. 00357325-01
Holddown 1 ceramic LPH HS-50 Item no. 00346320-01
Holddown 2 ceramic LPH HS-50 Item no. 00346310-01
Pneumatic ceramic centering unit for HS-50 Item no. 00356032-01
consisting of:
- solenoid valve, complete
- compressed air hose, approx. 2000 mm long
- Y-hose connection, manufacturer = Festo
PCB holddown retaining bracket, fixed
and movable conveyor side*) Item no. 00346320-01
Fastening screws for X-centering unit
2 x socket hex head cap screw M4 x 45 DIN 912
*) Only for reinstallation on PCB conveyor
Cable ceramic substrate centering HS-50, SHORT Item no.: 00356617-01
with MRLQWplug for connection
to the conveyor control, consisting of:
Solenoid valve cable and proximity switch cable for HS-50, complete, plug assembled
SIPLACE HS-50 2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS-50
01/01 Issue 2.4 Retrofit Kit, Tools
71
Cable ceramic substrate centering HS-50, LONG, Item no. 00357281-01,
with
MRLQW
plug for connection to the conveyor control,
consisting of:
Solenoid valve cable and proximity switch cable for HS-50, complete, plug assembled
NOTE:
The plugs are already completed assembled on both ends of the cable.
 $GGLWLRQDO0DWHULDO5HTXLUHG
)RUHDFKFHUDPLFVXEVWUDWHFHQWHULQJXQLW
if needed, lifting table plate with Item no. 00333620-03 for each processing
area
holes
Cable tie L x W = 140 x 3.6mm Item no. 00805141-01 5 - 6 units
Mounting pedestal, adhesive Item no. 00805103-01 2 - 3 units
if needed, compression spring
for holddown: 0.8 x 8.8 x 32 V2A Item no. 00200342-01 2 units for each
conveyor side
NOTE:
The screws to mount the holddowns are available from the earlier disassembly.
 7RROV$X[LOLDU\(TXLSPHQWDQG([SHQGDEOH0DWHULDOV
Set of Allen wrenches
Allen wrench, size 10*)
Metal square with arms approx. 160 mm long, parallel clamp,
plastic hammer (to align guide pillars)
if needed, adjustment plate for PCB conveyor
Loctite no. 243 (blue), Item no. 00334892-01 *)
Isopropyl alcohol
*) only necessary if the plate of the lifting table has to be exchanged
2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS-50 SIPLACE HS-50
2.5 Sequence of Retrofitting 01/01 Issue
72
 6HTXHQFHRI5HWURILWWLQJ
Perform all the work in the specified order.
 3UHSD UDWRU\6WHS
DANGER
Strictly adhere to the instructions in the DANGER text in Section 2.2 !
When a dual conveyor is involved, there is a risk of fingers or hands being pinched, crushed be-
tween the fixed side of conveyor 1 and the movable side of conveyor 2 when the conveyors are
travelling at maximum width.
It is not necessary to undock the movable component changeover tables to perform the retrofit-
ting. If you undock nevertheless, please note:
The X-gantry must always be moved / pushed out of the area of the component changeover table
before disconnecting the component changeover table.
Otherwise there will be a risk that the placement head may crash!!
High risk of injury exists from the blades and the tape deflector of the cutter, even when the ma-
chine has been turned off.
Never reach into the pneumatic cutter from below or into the empty-tape duct from above, not
even to resolve a problem (e.g., when tape is jammed before the component changeover table is
deinstalled).
Å Move the conveyor to maximum width so that you will be able to remove the lifting table plates
during a subsequent step.
If a dual conveyor is installed, move the conveyor 1 and 2 to maximum width.
Å The plates of the lifting tables have to be/remain lowered so that the springs of the holddowns
are not under tension during the following removal of the holddowns.
Å It is not necessary to undock the movable component changeover tables.
If you do this nevertheless, please heed the above DANGER text.
Å Turn the machine OFF, disconnect the machine from the mains and turn off the flow of com-
pressed air at the compressed air unit (see DANGER text in Section 2.2).