00192299-02.pdf - 第93页

SIPLACE HS-50 2 Retrofitting Instructions: Mechanical Ceramic Subs trate Centering HS-50 01/01 Issue 2.5 Sequence of Retrofitting 93  0DNLQJ&RQQHFW LRQVLQWKH3URF HVVLQJ$UH D Å Make the plu g-in co nnecti o…

100%1 / 124
2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS-50 SIPLACE HS-50
2.5 Sequence of Retrofitting 01/01 Issue
92
 6HULHV +DQGOLQJ763/D\LQJDQG&RQQ HF WLQJ&DEOH V
When series handling of conveyor control is available, the optional ceramic substrate centering
unit is connected directly to the conversion board in the pertinent conveyor area. The SHORT ca-
bles (Item no. 00356 617-01) in the retrofit kit of the ceramic substrate centering unit are used for
this purpose.
The conversion board is accessible when the lifting table plate is installed.
The cables running from the "conversion board conveyor" to the conveyor control in the machine
frame were already laid and connected at the factory.
Å Use the SHORT cables from the retrofit kit ((Item no. 00356 617-01).
Use a waterproof marker to indicate the allocation to the processing area on the pertinent cable
of proximity switch and solenoid valve: In accordance with the layout plan in Fig. 2.9.2 and Fig.
2.9.4, as appropriate, mark the pertinent connector designation,
- X34 am/ap or am/ao and X35 am/ap or am/ao and, if needed,
- C1 /C2 (for conveyor 1 / conveyor 2),
on the label of the pertinent connector.
Å In the PCB processing area, remove the cover from the conversion board and from the corre-
sponding cable pits.
Å Lay the cables from the conversion board in conveyor 1 or 2 further in the cable pit alongside
the fixed conveyor side -> further to the allocated solenoid valve or the centering unit.
Å Make the plug-in connections of the pertinent solenoid-valve and proximity switch cable on the
conversion board in the PCB in the PCB conveyor area (see Fig. 2.9.4 or Fig. 2.9.5).
Å Continue the work with Section 2.5.13.
SIPLACE HS-50 2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS-50
01/01 Issue 2.5 Sequence of Retrofitting
93
 0DNLQJ&RQQHFW LRQVLQWKH3URF HVVLQJ$UH D
Å Make the plug-in connection on the allocated solenoid valve.
Å Starting from the solenoid valve, run the pneumatic hose -> further in the crosswise cable pit
to the ceramic substrate centering unit (processing areas 2 and 3).
DANGER
Do not perform the cleaning work with alcohol near an open flame.
Å Using isopropyl alcohol, degrease the assembly surfaces for the mounting pedestal on the ver-
tical surface of the conveyor assembly (Fig. 2.5.14 -> 1) of each of the processing areas

.
Å In processing areas 2 and 3, degrease the surface for the mounting pedestal on the cable pit.
Å Mount the adhesive mounting pedestal.
.H\
1. Proximity switch cable and pneumatic hose
2. Cable and hose guide with strain relief device
3. 2 mounting pedestals, adhesive, with cable tie
2 Retrofitting Instructions: Mechanical Ceramic Substrate Centering HS-50 SIPLACE HS-50
2.5 Sequence of Retrofitting 01/01 Issue
94
CAUTION
The cables are not to be pinched when the lifting table plate is moving upward and they are not to
rub against the edges of the plate.
The strain on the plug-in connection of the proximity switch and the threaded hose coupling must
be relieved.
Å Plug the proximity switch cable into the pertinent centering unit.
NOTE:
Insert the connector of the proximity switch cable into the plug until you feel it engage.
Å Connect the pneumatic hose onto the threaded hose coupling of the X-centering unit.
Å Lay the hose and cable next to all X-centering units as shown in Fig. 2.5.14 -> 2. The strain on
the connections of the X-centering units must be relieved.
Å Use cable ties to secure the hose and cable exactly in this position (Fig. 2.5.14 -> 3).
Å Place the excess lengths of cables and hoses in the cable pits.
Å Using cable ties, fasten the solenoid valve cable in the longitudinal cable pit in such a manner
that the strain on the plug-in connection on the solenoid valve is relieved.
Å Run the cables and hoses on the rail of the conveyor width adjustment assy in processing ar-
eas 1and 4, as described below.
.H\WR)LJ
1. 1 Mounting pedestal with cable ties (see also Fig. 2.5.14)
2. Cables laid correctly on the rail
3. 2 mounting pedestals with cable ties
4. Ceramic substrate centering unit