4OM-996-007.pdf - 第105页
(24) Head Up/Down Section 1.3 Maintenance Spots Oil Inlets Every 3 Months Lubrication (DAPHNE EPONEX GREASE No. 1) Apply grease with a dispense gun. * Use No. 14 (olive) nozzle. Cam Follower of T op Block 3M26 Upper Sect…

(23) Nozzle Guide Section
1.3 Maintenance Spots
Nozzle Guide Cam Upper and Lower Surfaces 1M39
Every Month Lubrication (MOLYNOC GREASE AP1)
Replenish grease every month or after the machine has been stopped for
a long period of time (more than a week).
Apply grease evenly to the upper and lower surfaces of the nozzle guide
cam by hand or using a brush and perform an aging operation.
Refer to "4.5 "Aging" Tab" in "Section 6" of the instruction manual (Vol. 2:
Operation (Supervisor)) for the aging operation.
Note: Wipe off the dispersed grease.
Fig. 4A47
0509-002 1-41
AIM01ETRP

(24) Head Up/Down Section
1.3 Maintenance Spots
Oil Inlets
Every 3 Months Lubrication (DAPHNE EPONEX GREASE No. 1)
Apply grease with a dispense gun.
* Use No. 14 (olive) nozzle.
Cam Follower of Top Block 3M26
Upper Section of Linear Guide 3M27
Every 3 Months Lubrication (DAPHNE EPONEX GREASE No. 3)
Follow the steps below for the lubrication.
1. Close the air valve and allow the air to bleed out of the machine.
2. Rotate the rotary turret with the hand-rotating wheel to move the linear
guide to be lubricated between Stations #3 and #4
(Turret Angle: 108 degrees).
3. Set the dispense gun to "1".
4. Insert the nozzle to be used into the oil inlet and inject grease slowly,
spending about 10 seconds.
Note: Inject grease (quantity: 0.06 to 0.1 g) only once.
* Use the HL2-type nozzle.
Grease should be applied every 3 months after the initial month.
Fig. 4A48
0509-003 1-42
AIM01ETRP

1.3 Maintenance Spots
Lower Section of Linear Guide 3M28
Every 3 Months Lubrication (DAPHNE EPONEX GREASE No. 3)
Follow the steps below for the lubrication.
1. Close the air valve and allow the air to bleed out of the machine.
2. Rotate the rotary turret with the hand-rotating wheel to move the
linear guide to be lubricated between Stations #5 and #6
(Turret Angle: 108 degrees).
3. Set the dispense gun to "1".
4. Insert the nozzle to be used into the oil inlet and inject grease slowly,
spending about 10 seconds.
Note: Inject grease (quantity: 0.06 to 0.1 g) only once.
* Use the HL2-type nozzle.
Grease should be applied every 3 months after the initial month.
Oil Inlets
Fig. 4A49
0509-002 1-43
AIM01ETRP