4OM-996-007.pdf - 第85页

(1 1) Main Body Driving Section 1.3 Maintenance Spots Fig. 4A25 0509-003 1-22 AIM01ETRP Lubrication for Rotary T urret 1Y2 Every Y ear Oil Change (SYNTHESO HT220) Pull out the oil outlet hose from the machine and dischar…

100%1 / 417
1.3 Maintenance Spots
(10) Linear Measure Detection Section and Linear Measure Sensors in
Nozzle Detection Section
Filters 1M5
Every Month Checking
Check the filter. When it is extremely dirty,
replace it with a new one.
Note: Refer to "1.4.2 Filter Replacement of
Head Section" for the replacement.
Fig. 4A23
Fig. 4A24
0509-003 1-21
AIM01ETRP
Light Projecting/Receiving Glasses 1W8
Every Week Cleaning
When dirt and dust have accumulated on the
surfaces of the glass covers, wipe them off
with a lens cleaning cloth (standard
accessory part).
When the surfaces are heavily stained, apply
a small amount of absolute ethanol to a
cotton swab and wipe the surfaces gently
with the cotton swab.
(11) Main Body Driving Section
1.3 Maintenance Spots
Fig. 4A25
0509-003 1-22
AIM01ETRP
Lubrication for Rotary Turret 1Y2
Every Year Oil Change (SYNTHESO HT220)
Pull out the oil outlet hose from the machine and discharge the old oil into the
container. After that, supply new oil from Oil Inlet 1 or 2.
Note: Do not apply any air pressure to the internal area of the rotary turret
while oil is being discharged.
Otherwise, oil may leak out of the sealed section of the rotary turret.
Change the oil with new one after initial 500 hours and every 6,000 hours for
subsequent use.
The proper amount of oil is equivalent to "1/2" of the oil gauge. (11 or 12 liters)
Wipe off the oil pooled in the oil pan if necessary.
Precautions on Oil Replenishment
After the oil supply, turn on the power to activate the oil cooling pump.
After the machine is powered up, turn off the power of the machine (normal
shutdown operation).
Check the amount of oil when the oil level has become stable.
Note: Refer to "1.4.13 Lubrication of Rotary Turret" for the lubrication
procedure.
Oil Gauge of Rotary Turret 1W9
Every Week Inspection
Check the level of the oil gauge with the machine not powered.
If the level is not located at the center (red ball) of the oil gauge, replenish the oil.
The proper amount of oil is equivalent to "1/2" of the oil gauge.
Rotary Turret
Oil Outlet
Cooling Oil Filter
Oil Inlet 1
Oil Inlet 1
Oil Inlet 2
Oil Inlet 2
1.3 Maintenance Spots
Fig. 4A26
0509-002 1-23
AIM01ETRP
Cooling Oil Filter 2Y1
Every 2 Years Oil Filter Replacement
The oil filter must be replaced with a new one after initial 500
hours and every 12,000 hours for the subsequent use.
The new oil filter is attached as an accessory.
Note: Refer to "1.4.12 Replacement of Oil Filter" and "1.4.13
Lubrication of Rotary Turret" for how to replace the oil
filter.
Cooling Oil Filter
Nut
Cover