4OM-996-007.pdf - 第363页

0509-002 2-167 AIM01ETRP Error ID ltem Description 670601 Head Origin Offset T otal Designate Loop Exceeded Time. (Cause 1) Each head deviated from its origin position in comparison with the master head. (Remedy 1) Check…

100%1 / 417
Error ID ltem Description
670301 Head Skip Communication Error
670302 Head Skip Head Origin
670303 Head Skip Overtime Head Origin Return
670304 Head Skip Unselected Nozzle Drop
670305 Head Skip Dummy Nozzle
670306 Head Skip Manual Bypass
670307 Head Skip Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
670401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
670402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
670403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
670404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
670501 Master Head Offset Linear Measure System Was At High Position.
670502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0305-001 2-166 AIM01ETRP
3.3 Error IDs and Remedial Procedures
0509-002 2-167 AIM01ETRP
Error ID ltem Description
670601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
670701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
670702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
670801 Recog. Data Teach Recognition Error Code.
670901 Trash Teach Trash Teach Error Code.
670b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)" for details.
3.3 Error IDs and Remedial Procedures
(Pages 2-168 through 2-179 omitted intentionally)
4. Troubleshooting after Error Window (Recognition Error ID)
4.1 Typical Description
Table 4B11
Recognition Error ID Recognition Error Contents, Cause, and Remedy
02**1001** Component was not found.
(Cause 1) The feeder carriage is loaded with a feeder that contains components dif-
ferent from the specified ones.
(Cause 2) The vacuum suction force is too weak.
(Cause 3) An improper nozzle is selected for the components or vice versa.
Mismatching parameters are set in the nozzle type data and the compo-
nent library data.
(Remedy 1) Check if proper components are used.
(Remedy 2) Check the vacuum pressure.
(Remedy 3) Check the parameters in the nozzle type data and the component library
data.
02 **2100** Error in Outward Length Inspection
(Cause 1)
(Remedy 1)
(Continue to next page. )
*1 The recognition error IDs (IDs displayed in the "ERROR" window) are de-
scribed in the numerical order.
"*" will be filled with a numeric character.
*2 Described are the recognition error contents in the "ERROR" window.
*3 Described are the causes and remedial procedures of "*2 Recognition
Error Contents".
The causes and remedies are correlated as follows.
(Cause 1) Æ (Remedy 1)
(Cause 2) Æ (Remedy 2)
(Cause 3) Æ (Remedy 3)
*4 This indicates that the related contents are described subsequently on the
next page.
4. Troubleshooting after Error Window (Recognition Error ID)
0509-004 2-180 AIM01ETRP
*1
*2 *3
*4