Fig. 4A14-1 Front V iew of Machine Component Receiving Box 1D8 Daily Cleaning Clean with a vacuum cleaner . 1.3 Maintenance Spots 0305-001 1-14 AIM01ETRP

100%1 / 417
(4) Component Recognition Section
(5) Main Section of Machine Intermediate Base/Component Receiving Box
Fig. 4A14
1.3 Maintenance Spots
Use a suction force (a vacuum cleaner) for cleaning. Do
not blow air with an air gun.
If the component recognition section is dirty or
dusty, incorrect recognition will result.
Fig. 4A13
0412-002 1-13
AIM01ETRP
Notice
Fig. 4A14-1 Front View of Machine
Component Receiving Box 1D8
Daily Cleaning
Clean with a vacuum cleaner.
1.3 Maintenance Spots
0305-001 1-14 AIM01ETRP
(6) Cutter Section Component Drop Prevention Cover
1.3 Maintenance Spots
Component Drop Prevention Cover 1D9
Daily Cleaning
When components are scattered over the
cover, follow the steps below to remove them.
1. Set the timing angle of the rotary turret to
approx. 200 degrees and turn off the power
supply before cleaning work.
2. Remove three hexagon socket head bolts
(M4) and one knurled screw and pull the
cover toward the rear side of the machine to
detach.
3. Clean the cover with a vacuum cleaner, etc.
4. Attach the cover to the machine such that
the rail section of the cover is correctly
inserted into the guide section of the machine.
5. Attach the knurled screw first and then the
three hexagon socket head bolts (M4).
Pull out.
Guide Section
Guide Section
Rail Section
Hexagon Socket Head Bolt (M4)
Knurled Screw
Fig. 4A15 Rear View of Machine
0409-002 1-15
AIM01ETRP