4OM-996-007.pdf - 第149页
(3) Press the [ON] button entitled "MOVE". In 2 seconds, press the [EN- ABLE] button on the operation panel. The feeder carriage moves to the F1 side and the following sheet appears. Fig. 4A91-3 (4) Press the […

1.4 Maintenance Method
••
••
• Reference Mark Detection
(1) When the "Ref Mark Detect" tab is pressed in the "Fdr Crg" tab
sheet, the following tab sheet appears.
Fig. 4A91-1 "Ref Mark Detect" Tab Sheet
(2) When the [Start Reference Mark Detection] button is pressed in the
"Ref Mark Detect" tab sheet, the following sheet appears.
Fig. 4A91-2
0309-002 1-82 AIM01ETRP

(3) Press the [ON] button entitled "MOVE". In 2 seconds, press the [EN-
ABLE] button on the operation panel.
The feeder carriage moves to the F1 side and the following sheet
appears.
Fig. 4A91-3
(4) Press the [Next] button.
(5) Repeat the same steps and confirm that the reference mark can be
detected.
1.4 Maintenance Method
0309-002 1-83 AIM01ETRP

1.4.11 Cleaning of Linear Motor's Yoke Sides
Clean the yoke sides of the linear motor every month.
• Work Procedure
(1) Turn off the power switch of the machine and the air source.
(2) Open all the feeder work area safety doors.
(3) Clean the top and bottom sides of the upper yoke and the top side of
the lower yoke with a rag.
Fig. 4A92
(4) Push the feeder carriage by hand to move it sideways.
(5) Clean the top and bottom sides of the upper yoke and the top side of
the lower yoke with a vacuum cleaner or a rag.
1.4 Maintenance Method
• Do not bring any metal of high magnetizability close
to this. Otherwise, such metal will easily be magne-
tized and attracted, causing an injury to the operator
and/or a mechanical breakdown.
• Do not bring any magnetizable material close to this.
Those who ware implanted pacemakers should not
work inside the machine. Otherwise, the pacemaker
may be affected by magnetism, leading to a serious
accident.
CAUTION
WARNING
0509-005 1-84 AIM01ETRP
Feeder Carriage
Bottom Side of Upper Yoke
Top Side of Lower Yoke
Top side of Upper Yoke