Fig. 4A17 1.3 Maintenance Spots 0305-001 1-17 AIM01ETRP

(7) X/Y Table Section
X/Y Chute Up/Down Linear Guides Rails 3M5
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Wipe off the old grease with a rag and apply new
one by hand or using a brush.
There are four spots.
Grease should be applied every 3 months after
the initial month.
Surroundings of X/Y Base 1W4
Every Week Cleaning
Clean the surroundings of the X/Y table
with a vacuum cleaner.
Upper Surface of X/Y Ball Screw Cover 1W5
Weekly Cleaning
Clean the upper surface with a vacuum cleaner.
* Never blow air to the upper surface.
X/Y Ball Screw X Axis 3M3
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Wipe off the old grease with a rag and
apply new one by hand or using a brush.
Grease should be applied every 3 months
after the initial month.
X/Y Ball Screw Y Axis 3M4
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Wipe off the old grease with a rag and
inject new one into the grease nipple with
a grease gun.
* Use the U- and P-type attachments.
Grease should be applied every 3 months
after the initial month.
U Type P Type
Upper Surface of X/Y Table 1W3
Weekly Cleaning
Clean the upper surface with a vacuum
cleaner.
* Never blow air to the upper surface.
1.3 Maintenance Spots
Fig. 4A16
0309-002 1-16
AIM01ETRP

Fig. 4A17
1.3 Maintenance Spots
0305-001 1-17 AIM01ETRP

(8) Light Source Device for Component Recognition
1.3 Maintenance Spots
Lamp for Component Recognition 1Y1
Yearly Replacement
Replace the lamp every year or every 5,000 hours.
Refer to "1.4.7 Lamp Replacement of Light Source
Device for Recognition Lighting" for the replace-
ment.
Fig. 4A18
Fig. 4A19
0509-002 1-18